OPERATING GUIDELINES
F. Hot Air Gun Safety Feature
The systems’ hot air gun has a safety feature to limit the
temperature rise to no more than 3 degrees per second. The 3 degrees
per second limit is an industry standard recommendation to minimize
component damage due to a rapid increase of temperature. This
protection feature is activated by default and can be deactivated if
desired. Below are the procedures on activation/deactivation of this
safety feature:
1.
Turn “OFF” system and ensure all function switches are in “OFF”
position.
2.
Press and hold this two buttons. The Hot Air Gun Automate
Function Selector (“17” from the control panel) and the UP
button of the DESOLDER GUN TEMPERATURE adjustment
button.(“5” from the control panel) .
3.
With the two buttons held in the pressed position turn
“ON” the system by switching the Main Power Switch (“10”).
4.
Release the buttons when “SAFE OFF ” appears on the Hot Air
Gun Temperature Display/Hot Air Gun Airflow Display . Release
the buttons when this is displayed.
5.
The display below the word “SAFE” will indicate whether the
safety feature in “On” or “OFF” by displaying the corresponding
word on the Hot Air Gun Airflow Display The system will
proceed to standby mode.
6.
To switch the safety feature “On” or “OFF” simply repeat steps 1
to 5.
7.
The Status of the safety feature shall remain in effect until it is
manually changed by following procedure 1 to 5.