6.3 S Register
Number
Meaning
Range
Unit
Description
Default
0
Auto answer
0
1 - 255
Time
•
manual answer
•
Auto answer the incoming data
call after defined counting
0
1
RING count
0 - 255
Time
•
stored the RING count
0
2
Escape character
0
0 - 127
ASCII
•
disabled
•
use the ASCII value as escape
character
43
3
Carriage Return
0 - 127
ASCII
•
use the ASCII value as CR
13
4
Line Feed
0 - 127
ASCII
•
use the ASCII value as LF
10
5
Back Space
0 - 32
ASCII
•
use the ASCII value as BS
8
12
Escape sequence
Prompt time
0
1 - 255
20ms
•
do not check guard time
•
check guard time
50
25
DTR detection time
0 - 255
0.01sec
•
DTR recognized time
20
26
CS delay time
0 - 255
0.01sec
•
Delay between lost carrier and
Hang up (RTS to CTS)
1
37
V.110 speed set
5
6
15
17
27
50
•
5 = 1200bps
•
6 = 2400bps
•
15 = 4800bps
•
17 = 9600bps
•
27 = 19200bps
•
50 = 38400bps
50