CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 53 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
14. Power Frequency Magnetic Field immunity tests
??
Pass
performance Criteria : A
??
Basic Standard
: EN 61000-4-8 ( 1993 )
??
Generic Standard
: EN 55 024 :1998
??
Input Voltage, Frequency
: AC 230V, 50Hz
??
Temperature
: 19
°
C
??
Relative Humidity
: 51 %
??
Test Date
: Feb. 16, 2001
14.1 TEST RECORD
Power Frequency
Magnetic Field
Testing
duration
Coil
Orientation
Results
Remark
50Hz, 1A/m
1.0 Min
X-axis
Pass
Normal
50Hz, 1A/m
1.0 Min
Y-axis
Pass
Normal
50Hz, 1A/m
1.0 Min
Z-axis
Pass
Normal
14.2 TEST SETUP
Coil
EUT
0.8m
AMP
14.3 OPERATING CONDITION
Full system
Test Engineer :
ROXY CHOU