CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 11 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
5. Test of Conducted Powerline
Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 kHz on the 230V AC
power and return leads of the EUT according to the methods defined in European Standard EN 55022 Clause
9. The EUT was placed on a nonmetallic stand in a shielded room 0.8 meters above the ground plane as
shown in section 5.3. The interface cables and equipment positioning were varied within limits of reasonable
applications to determine the position producing maximum conducted emissions.
5.1 Description of Major Test Instruments
??
Test Receiver
( R&S ESH3 )
Attenuation
0 dB
Start Frequency
0.15 MHz
Stop Frequency
30 MHz
Step MHz
0.007 MHz
IF Bandwidth
9 KHz