The EUT was placed on a ground reference plane and was insulated from it by an insulating support about
0.1m thick. If the EUT is table-top equipment, it was located approximately 0.8m above the GRP.. The GRP.
was a metallic sheet (copper or aluminum) of 0.25 mm ,minimum thickness; other metallic may be used but
they shall have at least 0.65 mm thickness. It shall project beyond the EUT by at least 0.1m on all sides
and connected to the protective earth. In the SPORTON EMC LAB. we provided 1 mm thickness aluminum
ground reference plane or 1 mm thickness stainless steel ground reference plane. The minimum size of the
ground reference plane is 1 m x 1 m, the exact size depending on the dimensions of the EUT. It was
connected to the protective grounding system. The EUT was arranged and connected according to its
functional requirements. The minimum distance between the EUT and other conductive structures, except
the GRP. beneath the EUT, was more than 0.5 m. Using the coupling clamp, the minimum distance
between the coupling plates and all other conductive structures, except the GRP. beneath the EUT, was
more than 0.5 m. The length of the signal and power lines between the coupling device and the EUT was
1m or less.
11.2 Test on Power Line
a. The EFT/B-generator was located on the GRP.. The length from the EFT/B-generator to the EUT as not
exceed 1 m.
b. The EFT/B-generator provides the ability to apply the test voltage in a non-symmetrical condition to the
power supply input terminals of the EUT.
11.3 Test on Communication Lines
a. The coupling clamp is composed of a clamp unit for housing the cable (length more than 3 m), and was
placed on the GRP..
b. The coupling clamp provides the ability of coupling the fast transient/bursts to the cable under test.