![AOpen CDRW121032A Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/aopen/cdrw121032a/cdrw121032a_manual_2950638006.webp)
CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 6 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
2. Test Configuration of Equipment under Test
2.1 Test Manner
a. During testing, the interface cables and equipment positions were varied according to european
Standard EN 55022.
b. The SONY Monitor, DELL PS/2 Keyboard, LOGITECH PS/2 Mouse, HP Printer, ACEEX Modem, J-S
Earphone and EUT were connected to the AOpen PC for EMI test.
c. The HITACHI Monitor, DELL PS/2 Keyboard, PRIMAX PS/2 Mouse, KOKA Headset and EUT were
connected to the AOpen PC for EMS test.
d. Frequency range investigated: conduction 150 KHz to 30 MHz, radiation 30 MHz to 1000MHz.
2.2 Description of Test System
< EMI >
Support Unit 1. -- Monitor (SONY)
FCC ID
: AK8GDM17SE2T
Model No.
: GDM-17SE2T
Power Supply Type
: Switching
Power Cord
: Non-Shielded
Serial No.
: SP0013
Data Cable
: Shielded, 360 degree via metal backshells, 1.15m
Support Unit 2. -- PS/2 Keyboard (DELL)
FCC ID
: GYUM90SK
Model No.
: AT101W
Serial No.
: SP0019
Data Cable
: Shielded, 360 degree via metal backshells, 1.5m
Support Unit 3. -- PS/2 Mouse (LOGITECH)
FCC ID
: DZL211029
Model No.
: M-S34
Serial No.
: SP0108
Data Cable
: Non-Shielded, 1.8m