CE TEST REPORT
Report No. : C121401
SPORTON International Inc.
Page Number
: 56 of 62
TEL : 886-2-2696-2468
Issued Date
: Feb. 21, 2001
FAX : 886-2-2696-2255
15.3 TESTING REQUIREMENT AND PROCEDURE
The test was based on EN 61 000-4-11 (1994)
15.4 TEST CONDITIONS
1. Source voltage and frequency : 230V / 50Hz, Single phase.
2. Test of interval : 10 sec.
3. Level and duration : Sequency of 3 dips/interrupts.
4. Voltage rise (and fall) time : 1
?
5
?
s.
5. Test severity :
Voltage dip and
Interrupt reduction (%)
Test Duration
(ms)
30
500
60
100
100
10
100
80
100
5000
15.5 OPERATING CONDITION
Full system
Test Engineer :
ROXY CHOU