Operate the device only after having familiarized with its functions. Do not permit
operation by persons not qualified for operating the device. Most damages are the result
of unprofessional operation.

Please use the original packaging if the device is to be transported.
For safety reasons, please be aware that all modifications on the device are forbidden. If
this device will be operated in any way different to the one described in this manual, the
product may suffer damages and the guarantee becomes void. Furthermore, any other
operation may lead to short-circuit, burns, electric shock, crash, etc.

SAFETY INSTRUCTIONS

CAUTION!

Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching wires!

This device has left the factory in perfect condition. In order to maintain this condition and
to ensure a safe operation, it is absolutely necessary for the user to follow the safety
instructions and warning notes written in this user manual.
1. In order to guarantee the product’s life, please don’t put it in the damp places or even
the environment over 60degress.
2. Always mount this unit in safe and stable matter.
The qualified professionals are allowed to carry out the lamp installation, operation and
maintenance, but they must guarantee to operate in strict accordance with the instructions
referred to.

Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems.

If the device has been exposed to temperature changes due to environmental changes,
do not switch it on immediately. The arising condensation could damage the device. Leave
the device switched off until it has reached room temperatures.
This device falls under protection-class

. Therefore it is essential that the device be

earthed.
The electric connection must carry out by qualified person.

Make sure the power cord is never crimped or damaged by sharp edges. If this would be
the case, replacement of the cable must be done by an authorized dealer.

Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
During initial start-up some smoke or smell may arise. This is a normal process and does
not necessarily mean that the device is defective, it should decrease gradually.
Please don’t project the beam onto combustible substances.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively
replaced by the manufacturer or his service agent or a similar qualified person in order to
avoid a hazard.

Содержание ALED BSW CMY 400

Страница 1: ...ALED BSW CMY 400 USER MANUAL KEEP THIS USER MANUAL FOR FUTURE NEEDS...

Страница 2: ...case Clamps are optional please contact your dealer Please check carefully that there is no damage caused by transportation Should there be any questions please consult your dealer and don t install t...

Страница 3: ...ion operation and maintenance but they must guarantee to operate in strict accordance with the instructions referred to Important Damages caused by the disregard of this user manual are not subject to...

Страница 4: ...connected and must not be corroded 2 There must not be any deformations on the housing Fixations and installations spots ceiling suspension trussing 3 Mechanically moved parts must not show any trace...

Страница 5: ...SECTION Color 8 colors open Color half color function Color mixing system linear CMY CTO color mixing system Fixed gobos 12 fixed patterns ioen Rotating gobos 7 glass patterns each glass pattern can b...

Страница 6: ...DRAWING COLOR WHEEL FIXED GOBO WHEEL...

Страница 7: ...om fast to slow CH6 CH5 DIMMER 0 255 0 100 Dimmer CH7 CH6 STROBE 0 3 Close 4 103 Pulse strobe from slow to fast 104 107 Open 108 155 Open strobe from slow to fast 156 207 Close strobe from slow to fas...

Страница 8: ...4 25 29 Gobo 5 30 34 Gobo 6 35 39 Gobo 7 40 44 Gobo 8 45 49 Gobo 9 50 54 Gobo 10 55 59 Gobo 11 60 64 Gobo 12 65 69 Gobo 1 shaking slow to fast 70 74 Gobo 2 shaking slow to fast 75 79 Gobo 3 shaking s...

Страница 9: ...1 192 Stop 193 255 Slow to fast negative rainbow CH16 ROT FINE 0 255 CH17 CH15 PRISM 1 0 63 Close 64 127 Open CH18 CH16 PRISM 1 ROT 0 127 0 400 degree 128 187 Fast to slow positive rainbow 188 195 Sto...

Страница 10: ...fix the equipment Every clamp is locked by fastener of 1 4 kind Fastener can only be locked clockwise Attention Fasten a safety string to the additional hole of side aluminum piece The secondary acce...

Страница 11: ...h the item will set or modify setting Note Prevent damage the touch or TFT displayer Can not use sharp objects chick displayer Figure 3 Panel diagram 2 2 Operation 2 2 1 Operate light with touch or KE...

Страница 12: ...internal memory 2 2 3 Boolean parameter setting when the selected parameters is a Boolean value such as ON or OFF can directly modify setting by chick corresponding item the setting will been saved r...

Страница 13: ...er the page of DMX address setting range from 1 to 512 the address code shouldn t is not greater than 512 channels quantity otherwise the light will not been controlled Following is the operation Ente...

Страница 14: ...ight support 2 DMX Channel mode sample or extend Simple 16CH Default Expand 20CH or null DISP DISPLAY Set display Light support 2 language rotation display Enter page as shown in Figure9 to set parame...

Страница 15: ...not receive the data for DMX controller Figure 10 page of Test PAN range for 0 to 255 TILT range for 0 to 255 FOCUS range for 0 to 255 COLOR range for 0 to 255 GOBO range for 0 to 255 PRISM range for...

Страница 16: ...Restore all parameter to factory setting 2 3 6 STAT Status View status Enter the page as shown in Figure 12 Figure 12 page of status Work Mode Show the current working mode Address Show the current a...

Страница 17: ...focus channel value is suitable for the current projection distance 4 The lamps work intermittently Possible cause The internal circuit enters the protection state and the treatment is as follows Chec...

Страница 18: ...he unfinished current scene all the time that is start the next scene action it is best not to exceed 3 minutes in this state to ensure that multiple luminaires can run simultaneously During use if th...

Страница 19: ...s stated Or we aren t in charge of any result by misusing Any damage resulting by misuse is not within the Company s warranty Any fault or problem caused by neglecting the manual is also not in the ch...

Отзывы: