background image

1. The bulb does not light up (except LED light source)

Possible cause: The bulb is not completely cooled, or the bulb has reached the end of its life,

the treatment is as follows

Due to abnormal operation, the bulb is not completely cooled down, so let the lamp body
cool down for more than 10 minutes to make the inside completely return to normal state,
and then turn on the power again.

Check whether the bulb has reached the end of its life, and replace it with a new one

Check whether the bulb and the lighter circuit are leaking, falling off, or having poor
contact

Replace with a new lighter.

2. The light beam appears dim

Possible cause: The bulb has been used for a long time or the light path is not clean, the

treatment is as follows

Check whether the bulb has reached the end of its life, and replace it with a new one

Check whether the optical components or bulbs are clean, and whether there is dust on the
bulbs and other optical components. Regular cleaning and maintenance of the bulbs and
components in the lamps are required.

3. Fuzzy pattern projection

Check whether the electronic focus channel value is suitable for the current projection
distance.

4. The lamps work intermittently

Possible cause: The internal circuit enters the protection state, and the treatment is as

follows

Check whether the fan is operating normally or whether it is dirty, causing the internal
temperature of the lamp to rise

Check whether the internal temperature control switch is closed

Check whether the bulb has reached the end of its service life, and replace it with a new
one.

5. After the lamp is reset normally, it does not accept the control of the console

Possible cause: signal line failure or abnormal lamp parameter setting, the treatment is as

follows

Check the start address code and check the connection of the DMX signal line (whether the
signal line cable is intact, and whether the connection of the head is loose)

Add signal amplifier, add 120 ohm terminal resistance

6. The lamp can't start

Possible cause: bad power line, the treatment is as follows

Check whether the fuse on the power input socket is fused, replace the fuse

Lamps have poor line contact due to vibration during long-distance transportation

Check the input power, computer board and other plug-in devices.

2. Precautions for use

Check whether the local power supply meets the requirements of the rated voltage of the

Содержание ALED BSW CMY 400

Страница 1: ...ALED BSW CMY 400 USER MANUAL KEEP THIS USER MANUAL FOR FUTURE NEEDS...

Страница 2: ...case Clamps are optional please contact your dealer Please check carefully that there is no damage caused by transportation Should there be any questions please consult your dealer and don t install t...

Страница 3: ...ion operation and maintenance but they must guarantee to operate in strict accordance with the instructions referred to Important Damages caused by the disregard of this user manual are not subject to...

Страница 4: ...connected and must not be corroded 2 There must not be any deformations on the housing Fixations and installations spots ceiling suspension trussing 3 Mechanically moved parts must not show any trace...

Страница 5: ...SECTION Color 8 colors open Color half color function Color mixing system linear CMY CTO color mixing system Fixed gobos 12 fixed patterns ioen Rotating gobos 7 glass patterns each glass pattern can b...

Страница 6: ...DRAWING COLOR WHEEL FIXED GOBO WHEEL...

Страница 7: ...om fast to slow CH6 CH5 DIMMER 0 255 0 100 Dimmer CH7 CH6 STROBE 0 3 Close 4 103 Pulse strobe from slow to fast 104 107 Open 108 155 Open strobe from slow to fast 156 207 Close strobe from slow to fas...

Страница 8: ...4 25 29 Gobo 5 30 34 Gobo 6 35 39 Gobo 7 40 44 Gobo 8 45 49 Gobo 9 50 54 Gobo 10 55 59 Gobo 11 60 64 Gobo 12 65 69 Gobo 1 shaking slow to fast 70 74 Gobo 2 shaking slow to fast 75 79 Gobo 3 shaking s...

Страница 9: ...1 192 Stop 193 255 Slow to fast negative rainbow CH16 ROT FINE 0 255 CH17 CH15 PRISM 1 0 63 Close 64 127 Open CH18 CH16 PRISM 1 ROT 0 127 0 400 degree 128 187 Fast to slow positive rainbow 188 195 Sto...

Страница 10: ...fix the equipment Every clamp is locked by fastener of 1 4 kind Fastener can only be locked clockwise Attention Fasten a safety string to the additional hole of side aluminum piece The secondary acce...

Страница 11: ...h the item will set or modify setting Note Prevent damage the touch or TFT displayer Can not use sharp objects chick displayer Figure 3 Panel diagram 2 2 Operation 2 2 1 Operate light with touch or KE...

Страница 12: ...internal memory 2 2 3 Boolean parameter setting when the selected parameters is a Boolean value such as ON or OFF can directly modify setting by chick corresponding item the setting will been saved r...

Страница 13: ...er the page of DMX address setting range from 1 to 512 the address code shouldn t is not greater than 512 channels quantity otherwise the light will not been controlled Following is the operation Ente...

Страница 14: ...ight support 2 DMX Channel mode sample or extend Simple 16CH Default Expand 20CH or null DISP DISPLAY Set display Light support 2 language rotation display Enter page as shown in Figure9 to set parame...

Страница 15: ...not receive the data for DMX controller Figure 10 page of Test PAN range for 0 to 255 TILT range for 0 to 255 FOCUS range for 0 to 255 COLOR range for 0 to 255 GOBO range for 0 to 255 PRISM range for...

Страница 16: ...Restore all parameter to factory setting 2 3 6 STAT Status View status Enter the page as shown in Figure 12 Figure 12 page of status Work Mode Show the current working mode Address Show the current a...

Страница 17: ...focus channel value is suitable for the current projection distance 4 The lamps work intermittently Possible cause The internal circuit enters the protection state and the treatment is as follows Chec...

Страница 18: ...he unfinished current scene all the time that is start the next scene action it is best not to exceed 3 minutes in this state to ensure that multiple luminaires can run simultaneously During use if th...

Страница 19: ...s stated Or we aren t in charge of any result by misusing Any damage resulting by misuse is not within the Company s warranty Any fault or problem caused by neglecting the manual is also not in the ch...

Отзывы: