background image

CAUTION!

Never touch the device during operation!

The housing may heat up!

C

CAUTION!

N

Never look directly into the light source,

A

As sensitive persons may suffer an epileptic shock.

Please be aware that damages caused by manual modifications to be the device are
not subject to warranty. Keep away from children and non-professionals.

CLEANING AND MAINTENANCE

1. To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.
2. Do not spill water or other liquids into or on to your unit.
3. During long periods of non-use, disconnect the unit’s main power.
4. It should be installed in a well-ventilated place, at a distance of 50 centimeters or more
with the walls. At the same time, please check if the fan and ventilation holes are
unobstructed.

The following points have to be considered during the inspection
1) All screws for installing the devices or parts of the device have to be tightly connected

and must not be corroded.

2) There must not be any deformations on the housing. Fixations and installations

spots(ceiling, suspension, trussing).

3) Mechanically moved parts must not show any traces of wearing and must not rotate

with unbalances.

4) The electric power supply cables must not show any damage, material fatigue or

sediments. Further instructions depending on the installation spot and usage have to
be adhered by a skilled installer and any safety problems have to be removed.

CAUTION!

Disconnect from mains before starting maintenance operation!

In order to make the lights in good condition and extend the life time, we suggest a regular
cleaning to the lights.
1) Clean the inside and outside lens each week to avoid the weakness of the lights due

to accumulation of dust.

2) Clean the fan each week.
3) A detailed electric check by approved electrical engineer each three month, make sure

that the circuit contacts are in good condition, prevent the poor contact of circuit from
overheating.

We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth.
Never use alcohol or solvents.

Содержание ALED BSW CMY 400

Страница 1: ...ALED BSW CMY 400 USER MANUAL KEEP THIS USER MANUAL FOR FUTURE NEEDS...

Страница 2: ...case Clamps are optional please contact your dealer Please check carefully that there is no damage caused by transportation Should there be any questions please consult your dealer and don t install t...

Страница 3: ...ion operation and maintenance but they must guarantee to operate in strict accordance with the instructions referred to Important Damages caused by the disregard of this user manual are not subject to...

Страница 4: ...connected and must not be corroded 2 There must not be any deformations on the housing Fixations and installations spots ceiling suspension trussing 3 Mechanically moved parts must not show any trace...

Страница 5: ...SECTION Color 8 colors open Color half color function Color mixing system linear CMY CTO color mixing system Fixed gobos 12 fixed patterns ioen Rotating gobos 7 glass patterns each glass pattern can b...

Страница 6: ...DRAWING COLOR WHEEL FIXED GOBO WHEEL...

Страница 7: ...om fast to slow CH6 CH5 DIMMER 0 255 0 100 Dimmer CH7 CH6 STROBE 0 3 Close 4 103 Pulse strobe from slow to fast 104 107 Open 108 155 Open strobe from slow to fast 156 207 Close strobe from slow to fas...

Страница 8: ...4 25 29 Gobo 5 30 34 Gobo 6 35 39 Gobo 7 40 44 Gobo 8 45 49 Gobo 9 50 54 Gobo 10 55 59 Gobo 11 60 64 Gobo 12 65 69 Gobo 1 shaking slow to fast 70 74 Gobo 2 shaking slow to fast 75 79 Gobo 3 shaking s...

Страница 9: ...1 192 Stop 193 255 Slow to fast negative rainbow CH16 ROT FINE 0 255 CH17 CH15 PRISM 1 0 63 Close 64 127 Open CH18 CH16 PRISM 1 ROT 0 127 0 400 degree 128 187 Fast to slow positive rainbow 188 195 Sto...

Страница 10: ...fix the equipment Every clamp is locked by fastener of 1 4 kind Fastener can only be locked clockwise Attention Fasten a safety string to the additional hole of side aluminum piece The secondary acce...

Страница 11: ...h the item will set or modify setting Note Prevent damage the touch or TFT displayer Can not use sharp objects chick displayer Figure 3 Panel diagram 2 2 Operation 2 2 1 Operate light with touch or KE...

Страница 12: ...internal memory 2 2 3 Boolean parameter setting when the selected parameters is a Boolean value such as ON or OFF can directly modify setting by chick corresponding item the setting will been saved r...

Страница 13: ...er the page of DMX address setting range from 1 to 512 the address code shouldn t is not greater than 512 channels quantity otherwise the light will not been controlled Following is the operation Ente...

Страница 14: ...ight support 2 DMX Channel mode sample or extend Simple 16CH Default Expand 20CH or null DISP DISPLAY Set display Light support 2 language rotation display Enter page as shown in Figure9 to set parame...

Страница 15: ...not receive the data for DMX controller Figure 10 page of Test PAN range for 0 to 255 TILT range for 0 to 255 FOCUS range for 0 to 255 COLOR range for 0 to 255 GOBO range for 0 to 255 PRISM range for...

Страница 16: ...Restore all parameter to factory setting 2 3 6 STAT Status View status Enter the page as shown in Figure 12 Figure 12 page of status Work Mode Show the current working mode Address Show the current a...

Страница 17: ...focus channel value is suitable for the current projection distance 4 The lamps work intermittently Possible cause The internal circuit enters the protection state and the treatment is as follows Chec...

Страница 18: ...he unfinished current scene all the time that is start the next scene action it is best not to exceed 3 minutes in this state to ensure that multiple luminaires can run simultaneously During use if th...

Страница 19: ...s stated Or we aren t in charge of any result by misusing Any damage resulting by misuse is not within the Company s warranty Any fault or problem caused by neglecting the manual is also not in the ch...

Отзывы: