background image

-B284SB0*1K**P30  6/16-

24V

0V

24V

0V

PE

DP

DN

24V
0V

LG

24V

0V

L N FG

DP

DN

24V

0V

DP

DN

DP

DN

24V

0V

DP

DN

DP

DN

DP

DN

DP

DN

24V

0V

DP

DN

24V

0V

DP

DN

24V

0V

24V

0V

24V

0V

PE

24V

0V

L

N

FG

24V

0V

24V

0V

PE

DP

DN

24V

0V

DP

DN

24V

0V

A

B

LOAD

LINE

EAC-06-472

LOAD

LINE

EAC-06-472

EAC-06-472

LOAD

LINE

20

7.

5

20

8.4

8.3

M5

22.3

4.5

31

31

31

+0

-0.4

+0 -0.4

+0 -0.4

CAUTION

AnyWireASLINK master

24V DC stabilized

power supply 

24V DC 

stabilized

power supply 

General-purpose power

supply filter

(Use it if necessary.)

 

2-wire

terminal 

2-wire

terminal 

2-wire

terminal 

4-wire

terminal 

4-wire

terminal 

4-wire

terminal 

4-wire

terminal 

4-wire

terminal 

4-wire

terminal 

4-wire

terminal 

Terminator

If the total length of the sections
(A + B) where all the DP, DN, 24V, and 
0V lines run in parallel is more than 50m

Filter representation in the drawing

 Local power supply/branching

If the total length of the section 
where all the DP, DN, 24V, 
and 0V lines run in parallel is 
more than 50m

[Installation]

To mount this product, use the panel mounting holder included in the product, 
or the mounting screw hole of the sensor body.
To use a metal bracket, please contact us for further information.

Transmission connector

PA connector

(manufactured by JST)

B03B-PASK-1

2-M3 female thread

Depth 4

2-M5 female thread

Depth 4

φ

16.6 Height 4.5

M3 screw 
Tightening torque: 0.8N

m

M5 screw 
Tightening torque: 1.5N

m

Panel cutout dimensions

To mount several units

To mount a single unit 

 (n: number of units)

When you fasten the sensor body, provide a margin so as not to apply 
stress to the cable, connector, etc.
Do not excessively tighten the screws. Doing so may cause a fault of 
the equipment.

General-purpose power

supply filter

(Use it if necessary.)

 

31 × n + 3.5 × (n – 1)

55 or mor

e

Содержание ASLINKSENSOR

Страница 1: ...or serious injury A CAUTION indicates a potentially hazardous situation which if not handled correctly may result in personal injury or property damage If you set equipment parameter 1 alarm bit to en...

Страница 2: ...ction version Function version information is given on the lot label The design and contents of the lot label may vary depending on the product model and lot No Indication mode Model Functions Address...

Страница 3: ...should be connected to the DP DN terminal farthest from the AnyWireASLINK master unit Connect it correctly so as not to set the wrong polarity Connection with 2 wire non isolated terminals only Syste...

Страница 4: ...DC Notes on Combined Use of 4 Wire Isolated Terminal If the total length of the sections where all the DP DN 24V and 0V lines run in parallel in the power supply system is more than 50m connect an AS...

Страница 5: ...gth of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m If the total length of the sections A B where all the DP DN 24V and 0V lines run in parallel is more than 50m 4...

Страница 6: ...parallel is more than 50m Filter representation in the drawing Local power supply branching If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m In...

Страница 7: ...all be included in the total line length For address setting make sure that the specified number of transmission points is not exceeded If the specified number of transmission points is exceeded detec...

Страница 8: ...his unit to the AnyWireASLINK master unit A transmission signal is needed to write or read setting parameters Set parameters with the address writer with a transmission signal connected to the transmi...

Страница 9: ...scription 0 to 1000 0 to 100kPa Factory setting 400 40kPa Variable Description 0 to 1000 0 to 1000kPa Factory setting 400 400kPa B284SB 02 1KPP30 B284SB 02 1KNP30 B284SB 02 1KLP30 B284SB 02 1KPLP30 Va...

Страница 10: ...mit value The preset response time applies to both ON and OFF operations Input response time selection Equipment parameter 10 This parameter is used to set an alarm judgment monitoring time Alarm dete...

Страница 11: ...the master unit A bit corresponding to the status detail area turns ON depending on the contents of the alarm Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Window com...

Страница 12: ...ime Time Pressure detected by sensor Input 1 point type Input 1 point type Input 1 point type Input 2 points type Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Detecti...

Страница 13: ...plified replacement function does not work Check if the replacement slave unit is of the same type as that of the slave unit before the replacement Check if the function version for the replacement sl...

Страница 14: ...maximum transmission delay time is defined as this time word transmission cycle time Specifications 0 55 C 10 90 RH No condensation 25 75 C 10 90 RH No condensation Based on JIS B 3502 and IEC 61131...

Страница 15: ...s B284SB 01 1KPP30 B284SB 02 1KPP30 B284SB 01 1KNP30 B284SB 02 1KNP30 B284SB 01 1KLP30 B284SB 02 1KLP30 1kPa 0 1kPa 0 2kPa 0 1kPa B284SB 01 1KPLP30 B284SB 02 1KPLP30 Mounting panel 1 to 6mm Mounting b...

Страница 16: ...17 2018 2019 2020 UMA 14531AJ EN B284SB0 1K P30 16 16 Address Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by webs...

Отзывы: