background image

-B284SB0*1K**P30  4/16-

DP

DN

24V
0V

POWER IN

SLAVE

LG

24V

0V

L N FG

DP

DN

DP

DN

24V

0V

DP

DN

ANF-01

24V

0V

24V

0V

PE

AnyWireASLINK 

master

Black: 

DN

Red: 

DP

24V DC*

Example of mixed installation with 2-wire (non-isolated) and 

  4-wire (isolated) terminals

Black: DN

Red: DP

White: 0V

Green: 24V

16 points

Black: DN

Red: DP

Black: DN

Red: DP

1 point

Black: DN

Red: DP

1 point

4 points

Black: DN

Red: DP

Black: DN

Red: DP

Black: DN

Red: DP

2 points

2 points

8 points

4P link connector is 

convenient for 

branching.

The sum of the 

portions of DP, DN is 

the total line length.

The branching 

has no limitation.

AnyWireASLINK terminator

One terminator should be connected to the DP, DN 
terminal farthest from the AnyWireASLINK master unit.  
Connect it correctly so as not to set the wrong polarity.

2 points

2 points

2 points

2 points

Black: DN

Red: DP

Black: DN

Red: DP

Black: DN

Red: DP

2 points

2 points

2 points

8 points

Dedicated flat cable

1.25mm

2

 (4-wire)

To connect loads (e.g. I/O ports) that are 
controlled with a power supply other than 
the one used for the AnyWireASLINK 

system, always use a 4-wire (isolated) terminal.
Otherwise, malfunction may be caused.

ASLINK

filter

Gener

al-pur

pose 

po

w

er suppl

y f

ilt

er

24V DC*

[Notes on Combined Use of 4-Wire (Isolated) Terminal]

If the total length of the sections where all the DP, DN, 24V, and 0V lines run in 
parallel in the power supply system is more than 50m, connect an ASLINK filter 
(Type ANF-01) or a filter manufactured by COSEL Co., Ltd. (Type EAC-06-472) in 
series to the 24V and 0V lines at a position where these four lines start running in 
parallel.
This will improve noise resistance, suppress the adverse effects of crosstalk caused 
by transmitted signals, and stabilize signals.
The above filters must be inserted regardless of whether power is supplied to all 
terminals collectively from the power supply for the master or power is supplied to 
each terminal individually from their local power supply.

Insert the “ASLINK filter [Type ANF-01]” regardless of installation 
method and distance when complying with CE Standard.

Filter allowable current

ANF-01

MAX 5A/24V DC

Filter of COSEL Co., Ltd. EAC-06-472 MAX 6A/24V DC

Product

Type

Allowable power current

ASLINK filter

Terminator

AnyWire Type: ANF-01 Connection example

Power supply to the entire system

AnyWireASLINK master

24V DC stabilized

power supply 

General-purpose power

supply filter

(Use it if necessary.)

 

2-wire

terminal 

4-wire

terminal 

If the total length of the section 
where all the DP, DN, 24V, and 0V 
lines run in parallel is more than 50m

General-purpose 

power supply filter

CAUTION

Содержание ASLINKSENSOR

Страница 1: ...or serious injury A CAUTION indicates a potentially hazardous situation which if not handled correctly may result in personal injury or property damage If you set equipment parameter 1 alarm bit to en...

Страница 2: ...ction version Function version information is given on the lot label The design and contents of the lot label may vary depending on the product model and lot No Indication mode Model Functions Address...

Страница 3: ...should be connected to the DP DN terminal farthest from the AnyWireASLINK master unit Connect it correctly so as not to set the wrong polarity Connection with 2 wire non isolated terminals only Syste...

Страница 4: ...DC Notes on Combined Use of 4 Wire Isolated Terminal If the total length of the sections where all the DP DN 24V and 0V lines run in parallel in the power supply system is more than 50m connect an AS...

Страница 5: ...gth of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m If the total length of the sections A B where all the DP DN 24V and 0V lines run in parallel is more than 50m 4...

Страница 6: ...parallel is more than 50m Filter representation in the drawing Local power supply branching If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m In...

Страница 7: ...all be included in the total line length For address setting make sure that the specified number of transmission points is not exceeded If the specified number of transmission points is exceeded detec...

Страница 8: ...his unit to the AnyWireASLINK master unit A transmission signal is needed to write or read setting parameters Set parameters with the address writer with a transmission signal connected to the transmi...

Страница 9: ...scription 0 to 1000 0 to 100kPa Factory setting 400 40kPa Variable Description 0 to 1000 0 to 1000kPa Factory setting 400 400kPa B284SB 02 1KPP30 B284SB 02 1KNP30 B284SB 02 1KLP30 B284SB 02 1KPLP30 Va...

Страница 10: ...mit value The preset response time applies to both ON and OFF operations Input response time selection Equipment parameter 10 This parameter is used to set an alarm judgment monitoring time Alarm dete...

Страница 11: ...the master unit A bit corresponding to the status detail area turns ON depending on the contents of the alarm Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Window com...

Страница 12: ...ime Time Pressure detected by sensor Input 1 point type Input 1 point type Input 1 point type Input 2 points type Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Detecti...

Страница 13: ...plified replacement function does not work Check if the replacement slave unit is of the same type as that of the slave unit before the replacement Check if the function version for the replacement sl...

Страница 14: ...maximum transmission delay time is defined as this time word transmission cycle time Specifications 0 55 C 10 90 RH No condensation 25 75 C 10 90 RH No condensation Based on JIS B 3502 and IEC 61131...

Страница 15: ...s B284SB 01 1KPP30 B284SB 02 1KPP30 B284SB 01 1KNP30 B284SB 02 1KNP30 B284SB 01 1KLP30 B284SB 02 1KLP30 1kPa 0 1kPa 0 2kPa 0 1kPa B284SB 01 1KPLP30 B284SB 02 1KPLP30 Mounting panel 1 to 6mm Mounting b...

Страница 16: ...17 2018 2019 2020 UMA 14531AJ EN B284SB0 1K P30 16 16 Address Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by webs...

Отзывы: