-B284SB0*1K**P30  10/16-

Description

0

1

Factory setting: 0

Variable

B284SB-02-1KPP30, B284SB-02-1KNP30, B284SB-02-1KLP30, B284SB-02-1KPLP30

2

3

Variable

0

1

Description

Factory setting: 0

Variable

Unit

3 to 255

100ms

Factory setting: 50

Variable

Unit

0 to 255

10ms

Factory setting: 1

Hysteresis mode 

Positive logic (sensor value > upper limit value 

 ON)

Hysteresis is set from the input lower limit value (equipment 

parameter 3).

Window comparator mode

Positive logic (upper limit value > sensor value > lower limit value 

 

ON)

Hysteresis mode 

Negative logic (sensor value < upper limit value 

 ON)

Hysteresis is set from the input lower limit value (equipment 

parameter 3).

Window comparator mode

Negative logic (sensor value > upper limit value, lower limit value > 

sensor value 

 ON)

Input logic selection   

[Equipment parameter 9] 

B284SB-01-1KPP30, B284SB-01-1KNP30, B284SB-01-1KLP30, B284SB-01-1KPLP30

This parameter is used to set detection logic of input 0 and input 1.

Hysteresis mode 

Both input 0 and input 1: Positive logic (sensor value > upper limit value 

 ON)

*

Hysteresis is set from the input lower limit value (equipment parameter 3).

Window comparator mode

Both input 0 and input 1: Positive logic (upper limit value > sensor 

value > lower limit value 

 ON)

Hysteresis mode 

Input 0: Negative logic (sensor value < upper limit value 

 ON)

Input 1: Positive logic (sensor value > upper limit value 

 ON)

*

Hysteresis is set from the input lower limit value (equipment parameter 3).

Window comparator mode

Input 0: Negative logic (sensor value > upper limit value, lower limit 

value > sensor value 

 ON)

Input 1: Positive logic (upper limit value > sensor value > lower limit value 

 ON)

Hysteresis mode 

Input 0: Positive logic (sensor value > upper limit value 

 ON)

Input 1: Negative logic (sensor value < upper limit value 

 ON)

*

Hysteresis is set from the input lower limit value (equipment parameter 3).

Window comparator mode

Input 0: Positive logic (sensor value > upper limit value, lower limit 

value > sensor value 

 ON)

Input 1: Negative logic (upper limit value > sensor value > lower limit value 

 ON)

Hysteresis mode 

Both input 0 and input 1: Negative logic (sensor value < upper limit 

value 

 ON)

*

Hysteresis is set from the input lower limit value (equipment parameter 3).

Window comparator mode

Both input 0 and input 1: Negative logic (sensor value > upper limit 

value, lower limit value > sensor value 

 ON)

This parameter is used to set a time required to turn ON or OFF input relative to 

an upper/lower limit value. (The preset response time applies to both ON and 

OFF operations.)

Input response time selection   

[Equipment parameter 10] 

This parameter is used to set an alarm judgment monitoring time.

Alarm detection judgment is based on the settings of equipment parameters 11, 

12 and 14.

When an alarm condition is detected, the sensing level drop signal is sent to the 

master unit.  

*For details, refer to page 11 to 12.

Alarm monitoring time setting   

[Equipment parameter 11] 

This parameter is used to set an upper limit value for alarm judgment.

Alarm detection judgment is based on the settings of equipment parameters 11, 

12 and 14.

When an alarm condition is detected, the sensing level drop signal is sent to the 

master unit.  

*For details, refer to page 11 to 12.

Alarm upper limit setting   

[Equipment parameter 12] 

B284SB-01-1KPP30, B284SB-02-1KPP30

B284SB-01-1KNP30, B284SB-02-1KNP30

B284SB-01-1KLP30, B284SB-02-1KLP30

B284SB-01-1KPLP30, B284SB-02-1KPLP30

Variable

Description

0 to 999

0 to 99.9kPa

Factory setting: 1000

Variable

Description

0 to 999

-100 to 99.8kPa

Factory setting: 1000

Variable

Description

0 to 999

0 to -99.9kPa

Factory setting: 1000

Variable

Description

1000

Alarm judgment disabled 

1000

Alarm judgment disabled 

1000

1000

0 to 999

0 to 999kPa

Factory setting: 1000

Alarm judgment disabled 

Alarm judgment disabled 

This parameter is used to set a lower limit value for alarm judgment.

Alarm detection judgment is based on the settings of equipment parameters 11, 

12 and 14.

When an alarm condition is detected, the sensing level drop signal is sent to the 

master unit.  

*For details, refer to page 11 to 12.

Alarm lower limit setting   

[Equipment parameter 14] 

If an error occurs out of the range of 0kPa ±2.5% (rated pressure) in pressure 

release status, this function corrects zero point according to this status.

When the error is within the range of 0kPa ±2.5% (rated pressure), zero correction 

is not executed.

Zero correction command    

[Equipment parameter 15] 

Description

Normal use

Execution of zero correction

*After execution of zero correction, be sure to reset the variable to 0.

B284SB-01-1KPP30, B284SB-02-1KPP30

B284SB-01-1KNP30, B284SB-02-1KNP30

B284SB-01-1KLP30, B284SB-02-1KLP30

B284SB-01-1KPLP30, B284SB-02-1KPLP30

Variable

1

0

Variable

Description

1 to 1000

0.1 to 100kPa

Factory setting: 0

Factory setting: 0

Variable

Description

1 to 1000

-99.8 to 100kPa

Factory setting: 0

Variable

Description

1 to 1000

-0.1 to -100kPa

Factory setting: 0

Variable

Description

0

Alarm judgment disabled 

0

Alarm judgment disabled 

0

Alarm judgment disabled 

0

Alarm judgment disabled 

1 to 1000

1 to 1000kPa

Factory setting: 0

Содержание ASLINKSENSOR

Страница 1: ...or serious injury A CAUTION indicates a potentially hazardous situation which if not handled correctly may result in personal injury or property damage If you set equipment parameter 1 alarm bit to en...

Страница 2: ...ction version Function version information is given on the lot label The design and contents of the lot label may vary depending on the product model and lot No Indication mode Model Functions Address...

Страница 3: ...should be connected to the DP DN terminal farthest from the AnyWireASLINK master unit Connect it correctly so as not to set the wrong polarity Connection with 2 wire non isolated terminals only Syste...

Страница 4: ...DC Notes on Combined Use of 4 Wire Isolated Terminal If the total length of the sections where all the DP DN 24V and 0V lines run in parallel in the power supply system is more than 50m connect an AS...

Страница 5: ...gth of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m If the total length of the sections A B where all the DP DN 24V and 0V lines run in parallel is more than 50m 4...

Страница 6: ...parallel is more than 50m Filter representation in the drawing Local power supply branching If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m In...

Страница 7: ...all be included in the total line length For address setting make sure that the specified number of transmission points is not exceeded If the specified number of transmission points is exceeded detec...

Страница 8: ...his unit to the AnyWireASLINK master unit A transmission signal is needed to write or read setting parameters Set parameters with the address writer with a transmission signal connected to the transmi...

Страница 9: ...scription 0 to 1000 0 to 100kPa Factory setting 400 40kPa Variable Description 0 to 1000 0 to 1000kPa Factory setting 400 400kPa B284SB 02 1KPP30 B284SB 02 1KNP30 B284SB 02 1KLP30 B284SB 02 1KPLP30 Va...

Страница 10: ...mit value The preset response time applies to both ON and OFF operations Input response time selection Equipment parameter 10 This parameter is used to set an alarm judgment monitoring time Alarm dete...

Страница 11: ...the master unit A bit corresponding to the status detail area turns ON depending on the contents of the alarm Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Window com...

Страница 12: ...ime Time Pressure detected by sensor Input 1 point type Input 1 point type Input 1 point type Input 2 points type Hysteresis mode Equipment parameter 8 0 Positive logic Equipment parameter 9 0 Detecti...

Страница 13: ...plified replacement function does not work Check if the replacement slave unit is of the same type as that of the slave unit before the replacement Check if the function version for the replacement sl...

Страница 14: ...maximum transmission delay time is defined as this time word transmission cycle time Specifications 0 55 C 10 90 RH No condensation 25 75 C 10 90 RH No condensation Based on JIS B 3502 and IEC 61131...

Страница 15: ...s B284SB 01 1KPP30 B284SB 02 1KPP30 B284SB 01 1KNP30 B284SB 02 1KNP30 B284SB 01 1KLP30 B284SB 02 1KLP30 1kPa 0 1kPa 0 2kPa 0 1kPa B284SB 01 1KPLP30 B284SB 02 1KPLP30 Mounting panel 1 to 6mm Mounting b...

Страница 16: ...17 2018 2019 2020 UMA 14531AJ EN B284SB0 1K P30 16 16 Address Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by webs...

Отзывы: