background image

-BL296*B08F****V50  2/22-

A

1

B

2

C

3

D

4

E

5

F

6

G

7

H

8

I

9

J

10

K

11

L

12

Lot No. 19ECBNB

As a result of the addition of functions, indication of lot No. has been changed from 3 digits (conventional format: 
year and month only) to 6 digits or 7 digits.

The master unit compatible with the word transmission function provides areas for transmission and receiving of word 
data (numerical information) such as analog data and sensing level data.
Using this function enables reduction of occupancy of bit information area by word data.
To enable word transmission, it is necessary that the system should be configured only with slave units compatible with 
the word transmission function.
A slave unit incompatible with the word transmission function cannot be connected to the AnyWireASLINK system to 
conduct word transmission.
For slave units that handle word data, word address settings are required.

[About AnyWireASLINK Ver. 1.1]

[About Lot No.]

[About Word Transmission]

*

3  Some products have no indication of function version.

Year: Numbers
 

(Lower two digits of the Christian era)

Month: Alphabet (as per the table below)

“19E” means May 2019.

Single unit simplified replacement

*

1

Word transmission

*

1

*

2

Functions available with Ver. 1.1

*

1  To use these functions, the master unit compatible with each function is required.

 

For details, refer to this manual together with the manual for the master unit.

*

2  You can use this function with the word-transmission AnyWireASLINK unit connected.

 

To handle word data, word address settings are required for slave units.

 

It depends on slave units whether word address setting is enabled or not.

New functions have been added to AnyWireASLINK products in May 2019 onward. Also, for the purpose of 
differentiation of compatible functions, indication of product lot number (lot No.) has been changed.

Compatible functions vary depending on lot No. Please understand the following description thoroughly to use each 
product.

Functions added to Ver. 1.1 are as follows:

Example:

S/W version

Year and month

H/W version

Alphabet

Month

Function version

*

3

Содержание ASLINK BL296 B-08F V50 Series

Страница 1: ...ncluding the output unit and the output circuit may result in smoking or firing An external safety device such as a fuse must be installed CAUTION WARNING Note on use A separate Address Writer is requ...

Страница 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Single...

Страница 3: ...lacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified replacement f...

Страница 4: ...it simplified replacement Remote address change Detection of sensor cable disconnection Bit address setting Slave unit voltage drop Sensing level drop I O disconnection I O short circuit I O power sup...

Страница 5: ...ching length or branch number has no limitation Include the length of the cable provided with the terminal in the total line length Connect the terminator with polarity to the DP DN terminal farthest...

Страница 6: ...ing in parallel This will improve noise resistance suppress the adverse effects of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whethe...

Страница 7: ...Use it if necessary 2 wire terminal 4 wire terminal 4 wire terminal AnyWireASLINK master If the total length of the section where all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC...

Страница 8: ...andard terminal block Cover mounting hole Mounting hole Bottom Lot label Bottom Lot label Cover mounting hole Mounting hole I O indicators Infrared port Spring terminal block I O indicators Infrared p...

Страница 9: ...Power supply for terminal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the trans...

Страница 10: ...minal and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connecti...

Страница 11: ...and connected load drive The 24V terminal of the transmission line connection cable is internally connected to the 24V pin of the terminal block The 0V terminal of the transmission line connection ca...

Страница 12: ...s setting An address number is set as a beginning number from which part of the transmission frame is occupied to the terminal Set the address number within the range of bit address 0 to 254 For the i...

Страница 13: ...B 08F V50 Monitor Display If an error is indicated identify a cause of the error by checking lit flashing status with the table on the left and eliminate the cause of the error Once the cause of the...

Страница 14: ...will be in the range from 21 6 to 27 6V Recommended voltage is 26 4V Check the total length Review the total length and wire diameter of transmission line so that the load will not exceed the current...

Страница 15: ...rrent 30V DC 100mA Internal circuit To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Ot...

Страница 16: ...nnect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Otherwise malfunction may be caused E g Use...

Страница 17: ...nts 1024 words max Input 512 words Output 512 words Up to 128 units Detection of transmission line disconnection transmission line short circuit transmission power supply drop and duplicated unregiste...

Страница 18: ...4 6 8 10 12 16 14 2 3 5 BL296 B08F V50 18 22 24V 0V 0 2 1 3 24V 0V 24V 0V 24V 0V 4 6 5 7 4 6 1 4 7 62 6 Outside Dimensions Unit mm M3 6 42mm pitch compatible with crimp terminal of 6mm in width When...

Страница 19: ...4V 0V 24V 24V 0V 2 3 5 BL296 B08F V50 19 22 0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0 1 0V 2 3 0V 4 5 0V 6 7 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Страница 20: ...0V 24V 0V 0V 0V 24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 0V 0 1 0V 2 3 0V 4 5 0V 6 7 24V 0V 24V24V0V 24V24V0V 24V 0V 24V 24V 4 6 1 4 Unit mm Black DN Red DP White 0V Green 24V UL style...

Страница 21: ...24V 24V 24V 24V 24V 24V 24V 0V 0V 0V 0V 0 1 2 3 4 5 6 7 39 4 28 6 81 28 9 15 15 7 7 74 5 500 17 7 5 40 8 7 5 3 6 39 4 95 40 8 21 05 2 3 5 M ounting screw hole Unit mm DIN rail mounting For DIN rail mo...

Страница 22: ...inted in Japan 2015 2016 2017 2018 2019 UMA 11306AK EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website htt...