![Anodyne Electronics Manufacturing AWG08-001 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/anodyne-electronics-manufacturing/awg08-001/awg08-001_installation-and-operation-manual_2944908025.webp)
AWG08-001 Audio Warning Generator
Installation and Operation Manual
January 21, 2019 Rev: 1.01
Page 2-5
ENG-FORM: 805-0102.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.4.5
Emergency Audio Path Adjustments (Field Adjustable)
The emergency audio routing can be adjusted to change how the direct audio inputs (DIR AUD IN) connect
to the audio outputs (AUDIO OUT) during emergency mode. Refer to cautions section above for adjustment
limitations. Refer to Section 2.4 for an image of the switch locations.
In emergency mode the rated input levels will equal rated output levels. Emergency mode switch
settings can impact the connected audio systems normal operational routing requirements.
Connected unit specifications and emergency mode system routing requirements should be assessed
before changes are made to the EMERG MODE SUMMING switch configuration.
The acceptable switch configurations for the emergency audio pathways are listed below:
Emergency Audio Option
State
Switch S100*
Switch S101*
Dir Audio Input 1 Connected To
Audio Output 1
On
Off
Dir Audio Input 2 Connected To
Audio Output 2
Dir Audio Input 1 Connected To
Audio Output 1 & Audio Output 2
Off
On
Dir Audio Input 2 Connected To
None
Dir Audio Input 1 Connected To
Audio Output 1
Off
Off
Dir Audio Input 2 Connected To
None
*Note:
These settings are field adjustable between “On” and “Off” individually. ”On” implies the switch is
connected (Closed)
while “Off” implies the switch is disconnected (Open). Field adjustable settings are not