35 / 44
NT_ANEP_P3GU_07-12-2018
NT_ANEP_P4GU_VoLTE_EN_12-05-2022
35 / 48
(7) READING ADVANCED
GATEWAY PARAMETERS
CODE
90
See programming tables by
SMS
(only)
This procedure allows you to check the advanced settings of the P4GU VoLTE
device and GSM gateway.
Send the following SMS to P4GU : AN-GWU
⁕
xxx#90#
or :
AN-GWU Beginning of the programming chain
⁕
xxx# password string (default xxx = 0)
P4GU VoLTE Will send one or two text messages to the number that sent the
request, with the following data:
Values
(the values shown are
for illustrative purposes)
Signification
AN?GWU
*
XXX#90P4GU
*
start of string
211000501 Mar 19 2021 08:52:32
P4GU software version
ELS61-E R2 02.000 ARN 01.000.05
Radio module data
359206065733230#
Code IMEI
4G
ACT: Access Technology
208
MCC Code (Country Code)
20
MNC Code (Operator Code)
7537
TAC (Tracking Area Identifier)
LAC (Location Area Identifier)
7A69401
CELL (cell ID)
-108
RSRP (Received Reference Signal Power)
-15
RSRQ (Reference signal reception quality)
POW or BATT
POW or BAT POW (External Power Present)
BATT (External Power Supply Absence)
ONH or OFH
ONH (Line in use)
OFH (Line available)