PROGRAMMING BY
SMS
Code
Function
format
Descriptions / Informations
51
DISABLE BATTERY
CHARGE LEVEL
CONTROL
AN-GWU*
0#51#
Disabling the battery charge level control (of
the P4GU gateway)
Page 33
52
THRESHOLD
BATTERY
(5)
AN-GWU*
0#5x#
X: Choice of 0 to 1
0 = Alert enabled (default)
1 = Alert disabled
AN-GWU*
0#52*x#
X: Choice of 0 to 7
0 = 7 hour
1 = 6:30 a.m.
2 = 6:00 a.m.
3 = 5:30 a.m.
4 = 4 hour (default)
5 = 2.5 hours
6 = 1.5 hours
7 = 1:00 a.m.
(Minimum number of operating hours, in backed
up mode, guaranteed by the battery charge)
Below this threshold, a notification SMS is sent.
5R
READING OF THE
BATTERY CHARGE
LEVEL CONTROL
AN-GWU*
0#5R
Reading of the battery charge level control
(from the P4GU gateway)
61
TELEPHONE LINE
VOLTAGE
AN-GWU*
0#61*X#
X: choice from 0 to 1
0 = 36 VDC
1 = 52 VDC
Gateway reset required for validation ....
0#98#
TELEPHONE LINE
VOLTAGE READING
AN-GWU*
0#61R
Answer (example) AN?GWU*0#61*1#
=> Value of 1 (52V)
81
EXTERNAL
POWER SUPPLY
CONTROL
ACTIVATION (6)
AN-GWU*
0#81*XXYY#
Enabling External Power Control
XX = minutes of power failure (01 to 99)
YY = power restore minutes (01 to 99)
Page 34
DISABLE
EXTERNAL
POWER SUPPLY
CONTROL (6)
AN-GWU*
0#81*0#
Disabling the function
READING OF
THE CONTROL
POWER SUPPLY
EXTERNAL
(6)
AN-GWU*
0#81R
Reading the status of the power control
Response (example) AN?GWU*0#81*0105#
=> Value of 0105 (default)