6.5 ERROR CODES (CONTINUED)
Error
Code
Error Code Description
Diag.
Code
Notes
110
SLT Lockout
306 431
432 433
434 435
436 756
Electronic temperature limits exceeded. General overheating
issue. Check for pump operation, trapped air and heat ex-
changer blockages. Monitor temperatures of system to estab-
lish problem area.
429 818 Criteria for the safe reset of the error sub code 433 (see
above) has not been met. Allow the boiler to cool further be-
fore pressing reset again
305 412
550 551
754
Overheat protection circuit is open circuit (X18 STB). Check
connector is pushed fully onto control PCB
428 438
817
Maximum Delta T of system exceeded. Check pump opera-
tion and presence of trapped air in the heat exchanger. Flow
through heat exchanger may be restricted.
426 437
815
Flow temperature heat up gradient exceeded. Check pump
operation and presence of trapped air in the heat exchanger.
Flow through heat exchanger may be restricted.
427 816 Criteria for the safe reset of the error sub code 426 (see
above) has not been met. Allow the boiler to cool further be-
fore pressing reset again
420 421
819 820
Return temperature greater than fl ow temperature. Check that
the fl ow and return sensors are operating correctly
419 430
813 814
Flow temperature limit exceeded. Check for overheating is-
sues and fl ow sensor (B2) performance.
809 810
422 423
Flow temperature reading error. Temperature reading less
than 0
O
C or greater than 124
O
C . Check fl ow sensor (B2) and
replace if necessary.
425
812
Return temperature limit exceeded. Check for overheating is-
sues and return sensor (B7) performance.
424
811
Return temperature reading error. Temperature reading less
than 0
O
C or greater than 124
O
C . Check fl ow sensor (B7) and
replace if necessary.
111
Shutdown limit thermostat
Any
Heat exchanger temperatures have been exceeded. Investi-
gate fl ow rates and controls to determine causes of temporary
fault code.
125
Maximum boiler temperature
exceeded
Any
Flow temperatures have been exceeded. Appliance will
continue once temperatures have dropped below maximum
allowed limits.
126
DHW charging temperature
not reached
Any
Charging temperature never achieved. Check operation and
heat up times for DHW
127
DHW legionella temperature
not reached
Any
Check operation of legionella function and DHW system.
Legionella setpoint has not been achieved within 48 hours of
the legionella function operating. If using a secondary return
system and sensor, do not set the legionella function setpoint
too high, as the heat losses around the hot water pipework
may not permit this setpoint to be achieved
128
Loss of fl ame during opera-
tion
394
Flame lost in operation within the fi rst 7 seconds of the start
of the modulation phase. Check the CO
2
is set correctly and
check operation and condition of ionisation electrode.
854
Flame lost in operation after the fi rst 7 seconds of the start
of the modulation phase. Check the CO
2
is set correctly and
check operation and condition of ionisation electrode.
625
Flame lost in operation more than 24 times in a 24 hour pe-
riod. Check the preceding error codes for details on when the
ionisation current was lost. Check the operation of the ionisa-
tion electrode, gas supply, and fl ue system. Check that there is
suffi cient gas available to the heater at all times.