Maintenance
60
MAXXfl o EVO
6.2.10 BACK FLOW PREVENTION VALVE
•
Remove the 8 Torx screws holding the cover plate onto the air arm and gently pull cover away from the seal.
•
The Back Flow Prevention Valve (BFPV) is located inside the cover itself and can be slid out for inspection.
•
Inspect BFPV for damage and operation. Replace if necessary
•
Inspect air arm seal for damage. Replace if necessary
•
Assembly is the reverse
6.2.11 CIRCULATION PUMP (Q1)
•
Close the shut off valve before the pump, or if optional pressure sensor kit fi tted close off the shut off valves
either side of the pump
•
Drain off water from the DHW tank (approximately 30 litres) or if the optional pressure sensor kit is fi tted use
the drain points between the shut off valves
•
Remove the PWM and power connectors, using a small fl at blade screwdriver to lift the white tab before
pulling each connector free.
•
Undo the unions at the top and bottom of the pump body and remove pump.
•
Fit the new pump seals
• Replacement is the reverse
• Refi ll and bleed of air
• Operate the pump by pulling the electrical connector off the heat exchanger front fl ow sensor (B2)
When all sound of air has stopped, reconnect B2 sensor and press the reset for 1s
Pump Union
Pump Union
Flow Sensor (B2)
F
F
Содержание MAXXflo EVO CWH 30/201
Страница 2: ...General 2 MAXX o EVO Blank Page...