ON:OFF key 

Turns the scale power on/off. 

RE-ZERO key 

Sets the display to zero. When the weight is within 
±2% of the weighing capacity to the zero point at the 
power-on, the key will zero the scale. When the weight 
e2%, it will be subtracted as tare weight. 

MODE key 

Changes the weighing units. 

ENTER key 

Used for setting the upper and lower limit value for 
the comparator.   

Comparator 

Shows results using LO, OK or HI (red, green and 
yellow) after comparing the weighing value to the 
upper and lower limit value. 

STABLE indicator 

Turns on when the weight reading is stable. 

Polarity

 

Shows the polarity of the weighing value. 

NET indicator

 

Turns on when the net weight is displayed.

 

ZERO indicator 

Turns on at the center of zero point. At the net weight 

zero point, both the ZERO and NET turn on. 

Battery indicator 

Shows the remaining battery level in 3 steps when 
operated by batteries. 

Battery cover 

(on the bottom) 

Weighing pan 

ON:OFF key 

MODE key 

RE-ZERO key 

Calibration 

switch cover 

Display 

ENTER key 

Color bar 

Comparator 

STABLE indicator 

Polarity 

ZERO indicator 

Weighing units 

Battery indicator 

NET indicator 

Содержание HT-3000CL

Страница 1: ...1WMPD4003328...

Страница 2: ...ument Avoid installing the scale in direct sunlight excessive dust high humidity high temperature large temperature fluctuations or magnetic fields which may cause problems or malfunctions Drafts and...

Страница 3: ...erated in a commercial environment If this unit is operated in a residential area it may cause some interference and under these circumstances the user would be required to take at his own expense wha...

Страница 4: ...r comparing the weighing value to the upper and lower limit value STABLE indicator Turns on when the weight reading is stable Polarity Shows the polarity of the weighing value NET indicator Turns on w...

Страница 5: ...s may result in excessive force being applied to the load cell and could damage the scale Take care not to apply too much force to the weighing pan Be sure to lock the battery cover again after instal...

Страница 6: ...ify that the reading is zero If not press the RE ZERO key to zero the display When you use a container for weighing place an empty container on the weighing pan and press the RE ZERO key to zero the d...

Страница 7: ...ruple the minimum display from the zero point in grams Nine upper and lower values respectively can be stored Memory number is 1 to 9 Numerical values of the upper and lower limit value are common for...

Страница 8: ...isplaying end the device returns to weighing mode 6 Start comparing using the memory number changed to Confirming the Upper and Lower Limit Value 4 Press the MODE key to display the memory number to b...

Страница 9: ...oggle between plus and minus 8 Press the ENTER key to store the lower limit value The scale then displays the upper limit value after displaying end 9 Press the ENTER key at upper limit value display...

Страница 10: ...00 is an example and may be a different number This is the starting point of the function settings Key Operation MODE To select a function item RE ZERO To change the parameter of each item ON OFF To f...

Страница 11: ...the weighing units enabled or disabled as appropriate There are three types of taels HK general Singapore tael HK jewelry tael and Taiwan tael But one of them can be selected The order of units to be...

Страница 12: ...are not available for use with HT 300CL HK Hong Kong HK tael general is equal to Singapore tael A catty contains 16 taels Newton is a value calculated as follows Newton weight in gram x 9 80665 m s2...

Страница 13: ...function 1 Enables zero trucking function Key lock Misoperation prevention function lock 0 Disables key lock Upper and lower limit value settings and unit switching are available 1 Enables key lock U...

Страница 14: ...lay LED brightness Adjusts LED brightness for the comparator display Cpi 0 Dark 1 2 Bright Decimal point Selects the symbol used for the decimal point pnt 0 Dot 1 Comma Initialization init Resets sett...

Страница 15: ...ayed When calibrating using a weight select a calibration weight from the following The weight must be purchased separately by the customer HT 300CL 300 g 0 01 g HT 3000CL 3000 g 0 1 g HT 500CL 500 g...

Страница 16: ...ibration weight But if the calibration weight cannot be prepared change the gravity acceleration of your scale to the value of the area where the scale is used See The Value of Gravity Acceleration at...

Страница 17: ...ch to Clrgo display press the RE ZERO key again To reset the settings to factory settings proceed to the next step while 1Clrgo is displayed 3 Press the RE ZERO key while pressing and holding the MODE...

Страница 18: ...pply 4 x AA batteries R6P LR6 or AC adapter Battery life Approx 450 hours When using at 23 C with comparator disabled and using alkaline batteries Approx 220 hours When using at 23 C with comparator a...

Страница 19: ...acity 1550 0 15500 2550 0 25500 ct Minimum display 0 5 5 0 5 5 Weighing capacity 3 00 30 0 5 00 50 0 N Minimum display 0 01 0 01 0 01 0 01 The Value of Gravity Acceleration at Various Locations Amster...

Страница 20: ...4 1235 550485 A D AUSTRALASIA PTY LTD 32 Dew Street Thebarton South Australia 5031 AUSTRALIA Telephone 61 8 8301 8100 Fax 61 8 8352 7409 A D KOREA Limited 6 33 817 150 749 817 Manhattan Bldg 33 Gukjeg...

Отзывы: