Chapter 5 : FRONT PANEL DISPLAY MENUS DESCRIPTION (continued)
OCTO
²
/ QFX402
PAGE 36
8-7-6 [Stand by time] +
ENTER.
When the device any more detect a signal on the selected input, this one is set in the
STANDBY
mode after
the duration of your choice. Select a duration with
+
ENTER.
NOTE:
Select OFF to inactive this function.
8-7-7 [Stand by] +
ENTER.
Allows to set the device in
STANDBY
mode
.
To coming out the
STANDBY
mode , press one of the front
panel buttons.
8-8 [Erase memories] +
ENTER.
This function allows erasing all the NON-volatile image memories. Select
[YES]
and validate with
ENTER.
8-9 [Default value] +
ENTER.
This function allows setting the following functions to the factory settings. Select
[YES]
and validate with
ENTER.
FUNCTION
POSITION
input type
Computer HV/C.
used input
All used.
H sync load
All Hi-Z.
VCR mode
All off
output format
SXGA 60Hz 4/3.
output sync
H&V.
type of screen
4/3
test pattern
no
switching seamless
#1
pos. settings
0
aspect ratio in
4/3
aspect ratio out
1:1
brightness 128
black level
128
contrast 128
color 128
hue 128
under/overscan overscan
sharpness 3
master volume
192
audio source
auto follow
audio level
48
audio balance
32
auxiliary input
OFF
mute OFF
display logo
all ON
assignment all
none
key locking
all unlock
fade color
R, G, B = 0
RS232/LAN port
RS232