UG-570
AD9361 Reference Manual
| Page 52 of 128
Table 35. Gain Step Calibration Register Values vs. LO Frequency
LO Frequency
Range (MHz)
Step Description
Step
Value (dB)
Register Value
(hex)
Variable in Table 36, Table 37,
and Table 39
600 to 1300
Maximum LNA Gain
24
C0
Xx
LNA Gain difference word for Index 0
23
2E
Aa
LNA Gain difference word for Index 1
8
10
Bb
LNA Gain difference word for Index 2
3
6
Cc
LNA Gain difference word for
I
ndex 3
0
0
Dd
1300 to 3300
Maximum LNA Gain
24
C0
Xx
LNA Gain difference word for Index 0
22
2C
Aa
LNA Gain difference word for Index 1
8
10
Bb
LNA Gain difference word for Index 2
3
6
Cc
LNA Gain difference word for
I
ndex 3
0
0
Dd
2700 to 4100
Maximum LNA Gain
23
B8
Xx
LNA Gain difference word for Index 0
22
2C
Aa
LNA Gain difference word for Index 1
8
10
Bb
LNA Gain difference word for Index 2
3
6
Cc
LNA Gain difference word for
I
ndex 3
0
0
Dd
4000 to 6000
Maximum LNA Gain
20
A0
Xx
LNA Gain difference word for Index 0
18
24
Aa
LNA Gain difference word for Index 1
8
10
Bb
LNA Gain difference word for Index 2
3
6
Cc
LNA Gain difference word for
I
ndex 3
0
0
Dd
4.
Program the directly-addressable register values as shown in Table 36.
Table 36. Configure LNA Gain Step Parameters
Line Number
Command
Addr/Data
Comment
1
SPIWrite
145,0F
//Set maximum mixer gain index (always 0x0F)
2
SPIWrite
148,0E
//Maximum measurement time
3
SPIWrite
147,3F
//Maximum settling time
4
SPIWrite
158,0D
//Default RSSI measurement mode
5
SPIWrite
150,0E
//Maximum RSSI measurement time
6
SPIWrite
15D,xx
//Maximum LNA Gain (from Table 35)
Rev. A