Battery Removal and Replacement
19
Battery Replacement & Firmware Upgrade - 5.2” Modero ViewPoint Touch Panels
3.
Carefully remove the back cover of the device and detach the battery lead at the female battery connector
(FIG. 2). This will allow the back cover to be detached from the device.
Reconnecting the Battery to the MVP-5200i
1.
On the back cover, make sure that the battery connector wiring runs to the right.
Make sure that the excess battery wiring fits in the space to the bottom left of the battery placement
(FIG. 3).
2.
Make sure to seat fully the battery plug to the connector in the device (FIG. 2). If fingers cannot be used,
use a clean, nonconductive stick or probe to seat the connectors.
FIG. 2
Interior of MVP-5200i, including female battery connector
Battery Connector
Attach the residual voltage discharge adaptor (
SAA5966-27-A
) to the old battery and
allow any remaining charge to dissipate. Note that the adaptor may become warm to
the touch for up to 12 hours.
Do not place the old battery in the plastic bag (for return shipment), until it has cooled.
FIG. 3
Path of excess battery wiring
MVP-BP-5X battery placement
Resistor location
Excess battery
wiring path