Firmware Pages and Descriptions
167
VG-Series Modero Touch Panels
Refer to the
Step 2: Choosing a Master Connection Mode Setting
section on page 110 for more detailed
information on using the System Settings page.
System Settings Page Elements (Cont.)
Master Connection (Cont.):
Ethernet Mode
Sets the speed of the Ethernet connection to the panel.
• Choices are:
Auto
,
10 Half Duplex
,
10 Full Duplex
,
100 Half Duplex,
or
100 Full Duplex.
MAC Address
Displays a read-only field that is factory set by AMX for the built-in Ethernet
interface.
Type
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear.
ICSNet is not a supported option on this panel.
•
Ethernet
is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
•
USB
option cannot be used on Modero panels which are not equipped with a
rear USB port.
Mode
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
•
URL
- In this mode, enter the IP/URL, Master Port Number, and
username/password (if used) on the Master.
- The System Number field is read-only because the panel obtains this
information from the communicating Master.
•
Listen
- In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master’s communication signals.
- The System Number and Master IP/URL fields are red-only.
•
Auto
- In this mode, enter the System Number and a username/password
(if applicable). This mode is used when both the panel and the NetLinx
Master are on the same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
System Number
Allows you to enter a system number. Default value is 0 (zero).
(ETHERNET Only - disabled when USB is selected)
Master IP/URL
Sets the Master IP or URL of the NetLinx Master.
(ETHERNET Only - disabled when USB is selected)
Master Port Number
Allows you to enter the port number used with the NetLinx Master.
• Default value is 1319.
(ETHERNET Only - disabled when USB is selected)
Username/Password
If the target Master has been previously secured, enter the alpha-numeric string
(into each field) assigned to a pre-configured user profile on the Master.
This profile should have the pre-defined level of access/configuration rights.
Содержание Modero NXT-1500VG
Страница 4: ......
Страница 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Страница 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Страница 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Страница 250: ...Appendix 240 VG Series Modero Touch Panels...
Страница 251: ...Appendix 241 7 Modero Widescreen Touch Panels...