Upgrading Modero Firmware
127
VG-Series Modero Touch Panels
6.
Press the
Back
button to return to the Protected Setup page and press the on-screen
Reboot
button
to restart the panel and save any changes.
Step 3: Verify and Upgrade the panel firmware via an IP
1.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the System.
The default
System value is one.
2.
Right-click the associated System number (from the Workspace window) and select
Refresh
System
to detect of all devices on the current system, establish a new connection to the Master, and
refresh the System list with devices on that system.
3.
After the Communication Verification dialog window verifies active communication between the
PC and the Master, verify the panel appears in the
OnLine Tree
tab of the Workspace window
(FIG. 97).
The default Modero panel value is 10001
.
4.
If the panel firmware being used is not current, download the latest Kit file by first logging in to
www.amx.com
and then navigate to
Tech Center
>
Firmware Files
and from within the
Modero
section of the web page locate your Modero panel.
5.
Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you
have downloaded the Modero Kit file to a known location.
6.
From within Studio, select
Tools
>
Firmware Transfers > Send to NetLinx Device
from the Main
menu to open the Send to NetLinx Device dialog (FIG. 98). Verify the panel’s System and Device
number
values match those values listed within the System folder in the
OnLine Tree
tab of the
Workspace window.
7.
Select the panel’s KIT file from the
Files
section (FIG. 98).
8.
Enter the
Device
value associated with the panel and the
System
number associated with the Master
(
listed
in the OnLine Tree tab of the Workspace window
).
The Port field is greyed-out.
9.
Click the
Reboot Device
checkbox. This causes the touch panel to reboot after the firmware update
process is complete.
The reboot of the panel can take up 30 seconds after the firmware process has
finished.
10.
Click
Send
to begin the transfer. The file transfer progress is indicated on the bottom-right of the
dialog (FIG. 98).
FIG. 97
NetLinx Workspace window (showing connected Modero panel)
Showing a Master
firmware version and
device number
Showing the current Modero
panel firmware version and
device number
Shows NetLinx Studio
version number
The panel firmware is shown on the right of the listed panel.
Содержание Modero NXT-1500VG
Страница 4: ......
Страница 62: ...Touch Panel Accessories 52 VG Series Modero Touch Panels...
Страница 100: ...Installation Procedures 17 Panels 90 VG Series Modero Touch Panels...
Страница 178: ...Firmware Pages and Descriptions 168 VG Series Modero Touch Panels...
Страница 250: ...Appendix 240 VG Series Modero Touch Panels...
Страница 251: ...Appendix 241 7 Modero Widescreen Touch Panels...