Configuring Communication
74
7" Modero Widescreen Touch Panels
18.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
19.
Press the
Back
button to open the Protected Setup page.
20.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (
zero
for an unknown System Number) and the IP/URL of the
Master (Master Port Number is defaulted to
1319
).
1.
Press the blue
Type
field (
from the Master Connection section
) until the choice cycles to the word
Ethernet
(FIG. 70). Refer to the
System Settings Page
section on page 132 for more information
about the fields on this page.
2.
Press the
Mode
field until the choice cycles to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls
this value directly from the communicating target Master (virtual or not). A Virtual Master
system value can be set within the active AMX software applications such as: NetLinx Studio,
TPD4, or IREdit.
3.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
(obtained from
the Diagnostics - Networking Address dialog
of the NetLinx Studio application)
.
4.
Click
Done
to accept the new value and return to the System Settings page.
5.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
6.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
7.
Press the
Back
button to open the Protected Setup page.
8.
Press the on-screen
Reboot
button to both save any changes and restart the panel.
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP
from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP
Address from the IP Settings of the System Settings page.
The
DHCP/Static
field (in the IP Settings section of the System Settings page) must be set to
DHCP
to get Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the Protected Setup page) to both save any changes and
restart the panel.
After power-up, press the grey Front Setup Access button for
3 seconds
to access the Setup
page.
Navigate to the
Setup > Protected Setup > System Settings
page and note the newly
obtained Dynamic IP Address information from the IP Settings section. This information is
then entered into the URL List for the connected NetLinx Master.
2.
Toggle the
Type
field until
Ethernet
is selected (
from the Master Connection section of the System
Settings page
).
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
Содержание Modero NXD-CV7
Страница 4: ......
Страница 10: ...vi 7 Modero Widescreen Touch Panels Table of Contents...
Страница 58: ...Installation 48 7 Modero Widescreen Touch Panels...
Страница 200: ...Troubleshooting 190 7 Modero Widescreen Touch Panels...
Страница 206: ...Appendix A 196 7 Modero Widescreen Touch Panels...
Страница 217: ...Appendix B Wireless Technology 207 Modero Touch Panels...
Страница 218: ...Appendix B Wireless Technology 208 Modero Touch Panels...
Страница 219: ...Appendix 209 7 Modero Widescreen Touch Panels...