Firmware Pages and Descriptions
133
7" Modero Widescreen Touch Panels
System Settings Page Elements (Cont.)
IP Settings:
Sets the IP communication values for the panel and contains:
DHCP/Static
Sets the panel to either DHCP or Static communication modes.
•
DHCP (Dynamic Host Configuration Protocol)
assigns IP Addresses from
client stations logging onto a TCP/IP network via a DHCP server.
•
Static IP
is a permanent IP Address that is assigned to a node in a TCP/IP
network.
IP Address
Sets the secondary IP Address assigned to the panel.
Subnet Mask
Sets a subnetwork address to the panel.
•
Subnetwork mask
is the technique used by the IP protocol to filter messages
into a particular network segment (Subnet).
Gateway
Sets a gateway value to the panel.
•
Gateway
is a computer that either performs protocol conversion between
different types of networks/applications or acts as a go-between two or more
networks that use the same protocols.
Host Name
Sets the host name of the panel.
Primary DNS
Sets the address of the primary DNS server used for host name lookups.
•
DNS (Domain Name System)
is software that lets users locate computers on
a local network or the Internet (TCP/IP network) by host and domain. The
DNS server maintains a database of host names for its’ domain and their
corresponding IP Addresses.
Secondary DNS
Sets a secondary DNS value to the panel.
Domain
Sets the unique name on the Internet to the panel for DNS look-up.
• The panel belongs to the DNS domain.
Ethernet Mode
Sets the speed of the Ethernet connection to the panel.
• Choices are:
Auto
,
10 Half Duplex
,
10 Full Duplex
,
100 Half Duplex,
or
100 Full Duplex.
MAC Address
Displays a read-only field that is factory set by AMX for the built-in Ethernet
interface.
Master Connection:
Sets the NetLinx Master communication values:
Type
Sets the NetLinx Master to communicate with the panel via either USB or
Ethernet. This is based on the cable connection from the rear.
ICSNet is not a supported option on this panel.
•
Ethernet
is a CAT-5 cable (10/100Base T terminated in an RJ-45 connector)
used to network computers together and is used in most LAN (local area
networks). This description is also used to refer to both wired and wireless
communication.
•
USB
option cannot be used on Modero panels which are not equipped with a
rear USB port.
Mode
Cycles between the different connection modes (URL, Listen, and Auto)
(ETHERNET Only - disabled when USB is selected)
•
URL
- In this mode, enter the IP/URL, Master Port Number, and
username/password (if used) on the Master.
- The System Number field is read-only because the panel obtains this
information from the communicating Master.
•
Listen
- In this mode, add the Modero panel address into the URL List in
NetLinx Studio and set the connection mode to Listen. This mode allows the
Modero touch panel to "listen" for the Master’s communication signals.
- The System Number and Master IP/URL fields are red-only.
•
Auto
- In this mode, enter the System Number and a username/password
(if applicable). This mode is used when both the panel and the NetLinx
Master are on the same Subnet and the Master has its UDP feature enabled.
- Master IP/URL field is read-only.
Содержание Modero NXD-CV7
Страница 4: ......
Страница 10: ...vi 7 Modero Widescreen Touch Panels Table of Contents...
Страница 58: ...Installation 48 7 Modero Widescreen Touch Panels...
Страница 200: ...Troubleshooting 190 7 Modero Widescreen Touch Panels...
Страница 206: ...Appendix A 196 7 Modero Widescreen Touch Panels...
Страница 217: ...Appendix B Wireless Technology 207 Modero Touch Panels...
Страница 218: ...Appendix B Wireless Technology 208 Modero Touch Panels...
Страница 219: ...Appendix 209 7 Modero Widescreen Touch Panels...