background image

O p e r a t i o n / R e f e r e n c e   G u i d e

M o d e r o   T o u c h   P a n e l s

Modero

®

 CV7

G4 Touch Panels

NXD-CV7 and NXT-CV7

7” Modero Widescreen Video Touch Panels

L as t   R e vi s ed :   1 0 / 1 / 20 0 8

Содержание Modero NXD-CV7

Страница 1: ...Operation Reference Guide Modero Touch Panels Modero CV7 G4 Touch Panels NXD CV7 and NXT CV7 7 Modero Widescreen Video Touch Panels Last Revised 10 1 2008...

Страница 2: ...or after the RMA is cancelled will be refused AMX is not responsible for products returned without a valid RMA number AMX is not liable for any damages caused by its products or for the failure of its...

Страница 3: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...

Страница 4: ......

Страница 5: ...and Upgrade of the Internal NXT Components 19 Step 1 Remove the existing NXT Outer Housing 19 Step 2 Install the Compact Flash Memory card upgrade 21 Step 3 Install the new 802 11g CF Card and Antenna...

Страница 6: ...Devices 47 Panel Calibration 49 Calibrating the Modero Panel 49 Testing your Calibration 50 Configuring Communication 51 Modero Setup and System Connection 51 Configuring and Using USB with a Virtual...

Страница 7: ...Control to Interact with a G4 Panel 76 Using your NetLinx Master to control the G4 panel 78 Upgrading Modero Firmware 81 Upgrading the Modero Firmware via the USB port 81 Step 1 Configure the panel fo...

Страница 8: ...tings Page Security Options EAP TTLS 126 Wireless Settings Page Security Options EAP TLS 129 Client certificate configuration 131 System Settings Page 132 Programming 135 Button Assignments 135 Page C...

Страница 9: ...w of Wireless Technology 197 Terminology 198 EAP Authentication 201 EAP characteristics 201 EAP communication overview 202 AMX Certificate Upload Utility 203 Configuring your G4 Touch Panel for USB Co...

Страница 10: ...vi 7 Modero Widescreen Touch Panels Table of Contents...

Страница 11: ...bution of video either Composite or S Video data via Ethernet and audio to Modero touch panels located up to 200 feet 60 96 m from the breakout box CV7 panels are ideally suited for displaying full mo...

Страница 12: ...ing and control of any networked computer directly from the panel This gives the user the ability to launch digital music from a PC cruise the Internet check and respond to E mail open software files...

Страница 13: ...s CV7 and BASE 1 Constant current draw 2 4 A 12 VDC Startup current draw 3 6 A 12 VDC Memory factory default 64 MB SDRAM 64 MB Compact Flash upgradeable to 1 GB factory programmed Weight stand alone N...

Страница 14: ...pport On and Off Both the LEDs and pushbuttons are only available when using the default Button Trim Ring on the NXD panel Buttons NXD panels only 6 programmable pushbuttons Rear Panel Components Side...

Страница 15: ...erating Temperature 0 C 32 F to 40 C 104 F Operating Humidity 20 85 RH Storage Temperature 20 C 4 F to 60 C 140 F Storage Humidity 5 85 RH Included Accessories Installation Kit for 7 NXD panels KA2258...

Страница 16: ...B Compact Flash card FG2116 61 NXA CV7CF512M 512 MB Compact Flash card FG2116 62 NXA CV7CF1G 1 GB Compact Flash card FG2116 63 It is recommended that firmware KIT files only be transferred over a dire...

Страница 17: ...nsions HWD 1 50 x 5 55 x 4 88 3 81 cm x 14 10 cm x 12 40 cm Width when attached to mounting ears 6 65 16 89 cm Power Consumption 50mA with audio video input 23mA with no audio video Routed through NXA...

Страница 18: ...e for video capable panels only RJ 45 connector for Ethernet input from the control system 2 pin 3 5 mm Phoenix connector for in bound power Included Accessories Two 2 pin Phoenix connectors 41 5025 4...

Страница 19: ...f 3 for each channel An example of this cable is to strip the ends of 2 RCA audio cables and insert them into their respective locations on the Audio In port Either a balanced and GND or unbalanced an...

Страница 20: ...se balanced audio inputs and outputs usually on 3 pin XLR connectors A balanced audio signal consists of a pair of wires carrying the audio signal in anti phase with each other if one wire carries a p...

Страница 21: ...dio Video and a single 2 pin mini Phoenix connector for power Product Specifications FIG 9 Wiring the rear MIC OUT connector for use with Balanced Audio FIG 10 10 Foot Modero Table Top Cable Modero Ta...

Страница 22: ...side of the Modero Table Top Cable Maximum Table Top Cable Lengths for Modero Panels Panel Sizes 7 Panel 10 Panel 12 Panel 15 Panel 17 Panel Setup I Using a panel without a battery base Maximum cable...

Страница 23: ...ON TWO 4 PAIR 24 AWG STRANDED TINNED COPPER POLYETHYLENE INSULATION ELEMENT 2 1 PAIR 18 AWG STRANDED TNNED COPPER PVC INSULATION AND FOIL SHIELDED OVERALL PAPER BINDER AND FLEX PVC JACKET 9 PAIRS COMP...

Страница 24: ...ope CE and Japan TELEC 802 11b Wireless Interface Card Specifications Dimensions HWD 2 07 x 1 68 x 0 21 52 56 mm x 42 80 mm x 5 57 mm Weight 13 61 grams 0 030 lbs Description 2 4 GHz Direct Sequence S...

Страница 25: ...ses a default SSID of AMX Please follow your particular Wireless Access Point s instruction manual for the correct procedures to setup either a secured or unsecured connection The following table list...

Страница 26: ...p the product label NXA WC80211GCF Specifications Dimensions HWD 0 22 x 1 68 x 2 40 5 6 mm x 42 80 mm x 61 0 mm Weight 19 50 grams 0 043 lbs Description Wireless LAN Compact Flash Card with external P...

Страница 27: ...mpliant 1 2 5 5 11 DSSS CCK 6 9 12 18 24 36 48 and 54 OFDM Mbps data rates Radio Technology Using 802 11b communication DSSS Direct Sequence Spread Spectrum CCK Complementary Code Keying Using 802 11g...

Страница 28: ...0 FG5965 02 NXD CV10 FG2259 02 NXT CV10 FG2259 01 03 NXD CV7 FG2258 02 NXT CV7 FG2258 01 Included Accessories Double sided adhesive tape Mounting Template cutout 62 2255 04 NXA WC80211GCF Installation...

Страница 29: ...the existing NXT Outer Housing 1 Carefully detach all connectors from the rear of the touch panel and then gently place the touch panel LCD facedown onto a soft cloth to expose the under side of the b...

Страница 30: ...ard 7 Tilt the LCD panel back up to gain better access to the Tilt Bracket cover plate 8 In a single motion carefully pull both the Tilt Bracket cover plate and outer housing up and then out away from...

Страница 31: ...ve the new CF memory card from it s anti static bag 5 Grip the sides of the new CF memory card and firmly insert it into slot opening with the arrow facing towards the pins until the contact pins are...

Страница 32: ...h the CF metal cover FIG 21 and the metal plate on the underside of the terminal antenna These surfaces must be properly cleaned to provide good adhesion for the later installation of the wireless ant...

Страница 33: ...outer housing forwards until it is aligned over the outer housing installation holes Once installed and secured the tilt bracket prevents any further movement FIG 18 4 Gently press down on the housing...

Страница 34: ...late from the front of the panel 2 Place the LCD facedown on a soft cloth to expose the under side of the unit FIG 22 This step helps prevent scratching of the LCD 3 Firmly press down on both connecto...

Страница 35: ...edges of the outer housing 2 Insert and secure the four pan head Housing Screws back into their pre drilled holes by using a grounded Phillips head screwdriver 3 Slip the connector overlay back into t...

Страница 36: ...ero Power Station Although this product is included within the NXA BASE 1 Kit FG2255 05K extra NXT BP Power Packs FG2255 10 can be purchased separately as an optional accessory FIG 24 NXT BP Power Pac...

Страница 37: ...lly charge up to two batteries FIG 25 NXA BASE 1 Kit consists of one BASE 1 and a single NXT BP NXA BASE 1 Specifications Dimensions HWD 0 93 x 5 96 x 6 89 2 36 cm x 15 14 cm x 17 51 cm Power Requirem...

Страница 38: ...NXA BASE 1 below an NXT CV7 Panel 1 Power Off the panel before attempting to attach the NXA BASE 1 2 Place the battery base with battery onto a flat level surface 3 Turn the battery locking slider FIG...

Страница 39: ...g slider in the opposite direction This turns the latching mechanism and secures the panel to the base 9 Upon successful connection the AMX logo appears on the panel to indicate that the panel is prop...

Страница 40: ...charge recalibrate a battery Powering the NXT CHG FIG 30 NXT CHG Kit consists of one NXT CHG charger and two NXT BP batteries NXT BP and NXT CHG Specifications Dimensions HWD 1 13 x 8 63 x 11 81 2 86...

Страница 41: ...Review the Checking the NXT BP charge section on page 27 to confirm the percentage of charge remaining on the batteries 2 Provide power to the charger as outlined in the Powering the NXT CHG section o...

Страница 42: ...ration of the batteries is only done upon a user request from the Modero on screen Battery Base page 1 Place the selected battery securely into Slot 1 left slot until there is activity on the Slot 1 L...

Страница 43: ...ing that allows you if desired to change the default configuration of the NXD panel Faceplate to that with no button openings In order to install this included No Button Trim Ring you must first remov...

Страница 44: ...he No Button Trim Ring until all of the latches are securely inserted into their openings on the Faceplate and the No Button Trim Ring is securely fastened Verify the No Button Trim Ring is firmly ins...

Страница 45: ...along the top of the internal surface of the Faceplate to begin removing the Trim Ring Removing the Internal Faceplate from the panel exposes the pushbuttons openings left from an earlier removal of t...

Страница 46: ...is an optional metallic box that is secured onto a stud beam in a pre wall setting where no walls are present Installation procedures and configurations can vary depending on the installation environ...

Страница 47: ...ing the main NXD unit into the CB TP7 Installation of an NXD Touch Panel The NXD CV7 can be installed either directly into the optional CB TP7 or other solid surface environment using the two differen...

Страница 48: ...connecting the panel connections to their terminal locations and applying power Verify that the panel is receiving power and functioning properly to prevent repetition of the installation 5 Disconnec...

Страница 49: ...ng surface Refer to SP 2258 01 for detailed installation dimensions reproduced in FIG 38 It is recommended that you cutout the surface slightly smaller than what is outlined in the installation drawin...

Страница 50: ...ections to their terminal locations and applying power Verify the panel is receiving power and functioning properly to prevent repetition of the installation 7 Disconnect the terminal end of the power...

Страница 51: ...econnect the terminal RJ 45 Ethernet USB and any optional audio video wiring to their respective locations on either the NXA AVB ETHERNET Breakout Box Ethernet port or NetLinx Master 13 Reconnect the...

Страница 52: ...can make any necessary cutout adjustments 1 Prepare the area by removing any screws or nails from the surface before beginning the cutout process 2 Cut out the surface for the NXD Wall Mount unit usin...

Страница 53: ...l 9 Insert and secure four 4 40 Mounting Screws included into their corresponding holes located along the sides of the NXD CV7 using a grounded Phillips head screwdriver until the unit is secure and f...

Страница 54: ...iring by connecting the panel connections to their terminal locations and applying power Verify that the panel is receiving power and functioning properly to prevent repetition of the installation 5 D...

Страница 55: ...and damage the connector Wiring a power connection To use the 2 pin 3 5 mm mini Phoenix connector with a 12 VDC compliant power supply the incoming PWR and GND wires from the external source must be...

Страница 56: ...all Mount panels Audio Video RJ 45 Pinout Information Pin Wire Color Function Polarity 1 Orange White Right Audio In 2 Orange Right Audio In 3 Green White Video In 4 Blue Mic Out 5 White Blue Mic Out...

Страница 57: ...nnected a mouse cursor appears on the panel screen and its location corresponds to the mouse cursor position sent by the external USB mouse If a USB keyboard has been connected only on screen keyboard...

Страница 58: ...Installation 48 7 Modero Widescreen Touch Panels...

Страница 59: ...nitial Panel Page FIG 45 Calibrating the Modero Panel 1 Press and hold the grey Front Setup Access button FIG 46 for 6 seconds to pass over the Setup page and access the Calibration setup page FIG 47...

Страница 60: ...t to touch the crosshairs is the first on screen message Calibration successful is the second on screen message that appears On screen crosshairs used for calibration of the touch device after the cal...

Страница 61: ...urn to the Protected Setup page 7 Press the on screen Reboot button to restart the panel and incorporate any changes Before commencing verify you are using the latest NetLinx Master and Modero panel f...

Страница 62: ...on the panel to match those of the target Master FIG 50 Protected Setup page Before continuing open NetLinx Studio This program assists in developing a System Number Master IP URL and Master Port numb...

Страница 63: ...e association to the driver is done in the background When the panel is detected for the first time some user intervention is required during the association between panel and driver 1 After the insta...

Страница 64: ...e PC This window notifies you that the panel has been detected by the PC as a USB compliant device and the PC is installing an appropriate USB driver to establish a proper communication to the panel T...

Страница 65: ...ettings Control Panel and double click the System icon to launch the System Properties dialog 2 Select the Hardware tab and click on the Device Manager button to launch the Device Manager dialog Withi...

Страница 66: ...e USB driver has been properly configured Refer to the previous section for more information 2 Launch NetLinx Studio 2 x default location is Start Programs AMX Control Disc NetLinx Studio 2 NetLinx St...

Страница 67: ...esh System to re populate the list The panel will not appear as a device below the virtual system number in the Online Tree tab until both the system number used in step 8 for the VNM is entered into...

Страница 68: ...em entry A in FIG 57 and select Refresh System This causes a refresh of all project systems establishes a new connection to the Virtual Master and populates the System list with devices on your partic...

Страница 69: ...eless interface card and then communicate to the WAP using the Wireless Settings assigned within the Wireless Settings page The WAP communication parameters must match those of the pre installed wirel...

Страница 70: ...eld to open a Keyboard and enter the Host Name information 6 Press Done after you are finished assigning the alpha numeric string of the host name 7 Do not alter any of these remaining greyed out fiel...

Страница 71: ...uates to a unique Internet name for the panel and press Done when complete 12 Setup the security and communication parameters between the wireless card and the target WAP by configuring the Wireless S...

Страница 72: ...ted in a Descending order SSID Z to A Channel 11 to 6 Security WEP to Unknown Signal Excellent to None 4 Select a desired Access Point by touching the corresponding row The up arrow and down arrow wil...

Страница 73: ...ing the Modero s wireless card for unsecured access to a WAP200G 1 Power down the panel and follow the wireless card installation procedures outlined in the Installation and Upgrade of the Internal NX...

Страница 74: ...an SSID alpha numeric be entered Using this method causes network packets to be sent out as unencrypted text 8 Press the red SSID field FIG 62 to display an on screen Network Name SSID keyboard 9 In t...

Страница 75: ...ly values are pulled from some of the other user configurable Configuration Utility pages By default wireless Modero panels are configured for unsecured communication to a Wireless Access Point To pro...

Страница 76: ...blank the unit will attempt to connect to the first available WAP By default all WAP200Gs use AMX as their assigned SSID value One of the most common problems associated with connection to a WAP aris...

Страница 77: ...s the Generate button to launch the WEP Passphrase keyboard If you are wanting to have your target WAP other than an NXA WAP200G generate the Current Key Do not press the Generate button and continue...

Страница 78: ...ering a Current Key generated either by your target WAP or another Modero panel within the WEP Keys section touch the Key button to launch the WEP Key keyboard FIG 67 enter the characters and press Do...

Страница 79: ...ould be communicating with This pointing to a Master is done via the System Settings page where you configure the IP Address System Number and Username Password information assigned to the target Mast...

Страница 80: ...after you are finished assigning the alpha numeric string of the host name 9 Press the Primary DNS field to open a Keyboard enter the Primary DNS Address provided by your System Administrator and pre...

Страница 81: ...grey Front Setup Access button for 3 seconds to proceed to the Setup page 7 Select Protected Setup System Settings located on the lower left to open the System Settings page FIG 68 URL Uniform Resour...

Страница 82: ...9 4 Click the Communications Settings button to open the Communications Settings dialog 5 Click on the NetLinx Master radio button from the Platform Selection section to indicate that you are working...

Страница 83: ...ault System value is one 11 Right click on the Empty Device Tree System entry and select Refresh System to re populate the list 12 Power up your panel and press and hold the grey Front Setup Access bu...

Страница 84: ...tLinx 6 Enter a username and password into their respective fields if the target Master has been previously secured 7 Press the Back button to open the Protected Setup page 8 Press the on screen Reboo...

Страница 85: ...ode instructs the Modero to search for a Master that uses the same System Number assigned within the Master Connection section and resides on the same Subnet as itself 1 Toggle the blue Type field unt...

Страница 86: ...The Network Interface Select field is read only and displays the method of communication to the web Verify you have selected the proper interface connection as this field does not auto detect the con...

Страница 87: ...c string for the Web Control password 14 Press the Web Control Port field to open the Web Port Number keypad 15 Within the keypad enter a unique numeric value to be assigned to the port the VNC Web Se...

Страница 88: ...ername and password is required for access or configuration Both HTTP and HTTPS Ports are enabled by default via the Manage System Server page If the Master has been previously configured for secured...

Страница 89: ...nication you are using it can be found in either the Wired Ethernet System Settings IP Settings section within the IP Address field Wireless Wireless Settings IP Settings section within the IP Address...

Страница 90: ...lick OK to send the password to the panel and begin the session A confirmation message appears stating Please wait Initial screen loading The secondary window then becomes populated with the same G4 p...

Страница 91: ...he USB driver has been completed confirm the proper installation of the large Type A USB connector to the PC s USB port and restart your machine 2 After the CV7 panel powers up press and hold the grey...

Страница 92: ...panel to respond and completes the communication turning the System Connection icon green 8 Navigate back to the System Settings page Step 2 Prepare NetLinx Studio for communication via the USB port 1...

Страница 93: ...h panel files 1 Verify this direct USB connection Type A on the panel to mini USB on the panel is configured properly using the steps outlined in the previous two sections 2 With the panel already con...

Страница 94: ...is greyed out 10 Click the Reboot Device checkbox This causes the touch panel to reboot after the firmware update process is complete The reboot of the panel can take up 30 seconds after the firmware...

Страница 95: ...Address and Gateway information 2 Launch NetLinx Studio 2 x default location is Start Programs AMX Control Disc NetLinx Studio 2 NetLinx Studio 2 3 Select Settings Master Communication Settings from t...

Страница 96: ...ettings 17 Click Reboot from the Tools Reboot the Master Controller dialog and wait for the System Master to reboot The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporatio...

Страница 97: ...www amx com and then navigate to Tech Center Firmware Files and from within the Modero section of the web page locate your Modero panel 5 Click on the desired Kit file link and after you ve accepted t...

Страница 98: ...in the transfer The file transfer progress is indicated on the bottom right of the dialog FIG 82 11 Click Close after the panel reboots to return to the main program 12 Right click the associated Syst...

Страница 99: ...tly loaded on the selected panel read only Refer to the Project Information Page section on page 92 for more detailed information Panel Information Press the Panel Information button to access the Pan...

Страница 100: ...nels Refer to the Video Adjustment Page section on page 97 for more detailed information Battery Base Press the Battery Base button to access the Battery Base page where you can modify and monitor NXT...

Страница 101: ...the panel can remain idle before activating the sleep mode When the device goes into sleep mode the LCD is powered down Press the UP DN buttons to increase decrease the time until the panel times out...

Страница 102: ...ctive A Lock only appears on the icon if the panel has established a connection with a currently secured target Master requiring a username and password File Name Displays the name of the TPDesign4 pr...

Страница 103: ...ile Creation Date Displays the project creation date Revision Date Displays the last revision date for the project Last Save Date Displays the last date the project was saved Blink Rate Displays the f...

Страница 104: ...th Displays the pixel width being used to display the incoming video signal on the Modero panel Maximum available screen width on a CV7 Modero panel is 800 pixels Screen Height Displays the pixel heig...

Страница 105: ...ter to retain and save any time date modifications made on the Time and Date Setup page Time Display fields These fields display the time in three formats STANDARD STANDARD AM PM and 24 HOUR Date Disp...

Страница 106: ...t Master requiring a username and password Master Volume This section allows you to alter the current master volume level Use the UP DN buttons to adjust the volume level range 0 100 The Master Volume...

Страница 107: ...on the Setup page sets the Video properties of the incoming video signal from an NXA AVB ETHERNET Breakout Box Volume Page Elements Cont Analog Breakout Box Line In Level Allows you to adjust the curr...

Страница 108: ...th a currently secured target Master requiring a username and password Settings The Default Settings button sets the video settings to their default values indicated in this table The Undo Changes but...

Страница 109: ...s and minutes Panel Shutdown The Panel Shutdown UP DN buttons alter the timeout value in minutes This value determines the number of minutes that would need to pass before the panel automatically shut...

Страница 110: ...ttery Level field indicates the level being used to report the charge status level back to the NetLinx Master on set in TPD4 Battery Power Brightness Limit The DISABLE DISABLED button acts as a power...

Страница 111: ...to access the Passwords Setup page where you can specify up to five security passwords Default password is 1988 Refer to the Password Setup Page section on page 108 for more detailed information Calib...

Страница 112: ...ure focuses on direct telnet communication to the panel Use the Front Button Setup Access button to activate the grey Front Setup Access button located below the LCD to access the firmware pages Defau...

Страница 113: ...C server that allows them to accept a connection from any other device running a VNC client Once a connection is established to that target device the client can control the touch panel remotely FIG 9...

Страница 114: ...hen a direct Ethernet connection is being used for communication to the web This is a default setting if no wireless interface card is detected by the panel Wireless is used when a wireless card is de...

Страница 115: ...alue between the Minimum and Maximum DIM Mode values delivers an average light level The DIM mode Min Level can never exceed the DIM Mode Max Level Sensor Setup Page Elements Back Saves the changes an...

Страница 116: ...htness Level range 0 100 The position of this bargraph can never exceed that of the Dim Mode Max Level Dim Mode Minimum Brightness Allows you to alter the sensitivity of the Modero panel light sensor...

Страница 117: ...from the room fixtures with your body Take note of the drop in the lighting level being detected by the panel in response to your movements Sensor Setup Page Elements Cont Wake Panel On Motion Sense T...

Страница 118: ...ing of the room is at 40 FIG 98 Password Setup page Password Setup Page Elements Back Saves the changes and returns you to the previously active touch panel page Connection Status icon This visual dis...

Страница 119: ...t Modero firmware some encryption and security features may may not be supported depending on the type of wireless card being used FIG 99 Calibration page actually 3 separate screens The request to to...

Страница 120: ...Text Static WEP 64 bit and 128 bit key lengths WPA PSK EAP security with and without certificates WAP SIte Survey FIG 101 Wireless Settings page reads from and assigns values to the WAP Wireless Sett...

Страница 121: ...S server maintains a database of host names for its domain and their corresponding IP Addresses SECONDARY DNS sets the secondary DNS value to the panel Primary DNS Sets the address of the primary DNS...

Страница 122: ...opens the Static WEP Settings dialog FIG 103 The following fields are required SSID Encryption method Passphrase WEP Key assignment and Authentication method Refer to the following Wireless Settings P...

Страница 123: ...get WAP Pressing the EAP TTLS button opens the EAP TTLS Settings dialog FIG 110 The following fields are required SSID Identity Password and Inner Authentication Type Refer to the following Wireless S...

Страница 124: ...ph has been replaced with a descriptions None Poor Fair Good Very Good and Excellent Green color text indicates better communication quality It reports the quality of the signal over the air direct se...

Страница 125: ...AP and then assigned to all panels in a wireless network that are communicating to the same target WAP This is required by the WAP before the panel is permitted to join the wireless network It is case...

Страница 126: ...oin the wireless network It is case sensitive and must not exceed 32 characters which may be any keyboard character Make sure this setting is the same for all points in your wireless network This uniq...

Страница 127: ...se will not match those created on the Modero panels Note The code key generator on Modero panels use the same key generation formula The passphrase generator is case sensitive Default Key Cycles thro...

Страница 128: ...on all panels and then enter the panel produced WEP key manually into the Wireless Access Point Use the on screen keyboard s Clear button to completely erase any previously stored key information Aut...

Страница 129: ...ey tool section on page 61 for more information on using this feature Refer to FIG 106 for an example of what a typical EAP LEAP system configuration page would like Wireless Security WPA PSK Settings...

Страница 130: ...ed to a RADIUS server which does not support the specified EAP type and or may not have the proper user identities configured Identity When pressed the panel displays an on screen keyboard which allow...

Страница 131: ...tificate automatically the first time that the panel tries to authenticate itself Automatic certificate downloading is more convenient but slightly less secure since its the certificate which is trans...

Страница 132: ...hich allows you to enter an EAP Identity string which is how the panel identifies itself to the Authentication RADIUS Server This information is similar to a username used to login to a secured server...

Страница 133: ...transfer it into the panel using the AMX Certificate upload application PAC File Location This field is used when the previous Automatic PAC Provisioning option has been Disabled When pressed the pane...

Страница 134: ...red in a specific directory that the user cannot control or change The most secure connection method uses a server certificate If no server certificate will be used then this field should be left blan...

Страница 135: ...els in a wireless network that are communicating to the same target WAP This is required by the WAP before the panel is permitted to join the wireless network It is case sensitive and must not exceed...

Страница 136: ...fies itself to the Authentication RADIUS Server This information is similar to the password entered to gain access to a secured workstation Use the on screen keyboard s Clear button to completely eras...

Страница 137: ...ion on page 205 for further details on these security options Refer to the Using the Site Survey tool section on page 61 for more information on using this feature Pressing the EAP TTLS button opens t...

Страница 138: ...an on screen keyboard which allows you to enter the network password string specified for the user entered within the Identity field This is also how the panel identifies itself to the Authentication...

Страница 139: ...information on using this feature Pressing the EAP TLS button opens the EAP TLS Settings dialog FIG 111 FIG 111 Wireless Settings page EAP TLS security method Wireless Security EAP TLS Settings SSID S...

Страница 140: ...tton to completely erase any previously stored network path information Client Certificate When pressed the panel displays an on screen Client Certificate File Location keyboard which allows you to en...

Страница 141: ...e The following table shows the possible file extension used for each certificate type Client Certificate Configuration Certificate Configuration Client Certificate Field Private Key Field Single file...

Страница 142: ...Type Supported Certificate Authority field PEM and DER Client Certificate field PEM and DER Private Key field PEM DER and PKCS12 FIG 112 System Settings page showing default values reads and assigns v...

Страница 143: ...thernet Mode Sets the speed of the Ethernet connection to the panel Choices are Auto 10 Half Duplex 10 Full Duplex 100 Half Duplex or 100 Full Duplex MAC Address Displays a read only field that is fac...

Страница 144: ...HERNET Only disabled when USB is selected Master IP URL Sets the Master IP or URL of the NetLinx Master ETHERNET Only disabled when USB is selected Master Port Number Allows you to enter the port numb...

Страница 145: ...buttons 1 Off state and 2 On state Level Range 1 600 Default level value 0 255 can be set up to 1 65535 Address port Range 1 100 These button assignments can only be adjusted in TPD4 and not on the p...

Страница 146: ...o the named hide effect Syntax PHE popup page name hide effect name Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On hide effect name Refers to the popup effec...

Страница 147: ...popup page Popup1 on the current page PPG Toggle a specific popup page on either a specified page or the current page If the page name is empty the current page is used see example 2 Toggling refers...

Страница 148: ...xample 2 If the popup page is already on do not re draw it This command works in the same way as the Show Popup command in TPDesign4 Syntax PPN popup page name page name Variable popup page name 1 50...

Страница 149: ...oordinate y coordinate Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On Example SEND_COMMAND Panel PSP Popup1 100 0 Sets the Popup1 show effect x coordinate va...

Страница 150: ...command works in the same way as the Toggle Popup command in TPDesign4 Syntax PPOG popup page name page name Variable popup page name 1 50 ASCII characters Name of the popup page page name 1 50 ASCII...

Страница 151: ...0 0 04 Dark Red 127 0 0 05 Very Dark Red 95 0 0 06 Very Light Orange 255 128 0 07 Light Orange 223 112 0 08 Orange 191 96 0 09 Medium Orange 159 80 0 10 Dark Orange 127 64 0 11 Very Dark Orange 95 48...

Страница 152: ...e 0 0 159 52 Dark Blue 0 0 127 53 Very Dark Blue 0 0 95 54 Very Light Purple 128 0 255 55 Light Purple 112 0 223 56 Purple 96 0 191 57 Medium Purple 80 0 159 58 Dark Purple 64 0 127 59 Very Dark Purpl...

Страница 153: ...Grey14 17 17 17 87 Black 0 0 0 255 TRANSPARENT 99 53 99 Default Font Styles and ID Numbers Font ID Font type Size Font ID Font type Size 1 Courier New 9 19 Arial 9 2 Courier New 12 20 Arial 10 3 Couri...

Страница 154: ...nu Bottom Rounded 55 Circle 105 Menu Bottom Rounded 65 Circle 115 Menu Bottom Rounded 75 Circle 125 Menu Bottom Rounded 85 Circle 135 Menu Bottom Rounded 95 Circle 145 Menu Bottom Rounded 105 Circle 1...

Страница 155: ...ded 25 Menu Top Rounded 175 Menu Right Rounded 35 Menu Top Rounded 185 Menu Right Rounded 45 Menu Top Rounded 195 Menu Right Rounded 55 Neon Active L Menu Right Rounded 65 Neon Active S Menu Right Rou...

Страница 156: ...NI vt addr range start state end state time Variable variable text address range 1 4000 start state Beginning of button state 0 current state end state End of button state time In 1 10 second interval...

Страница 157: ...mple SEND_COMMAND Panel BAT 520 1 Enter City Appends the text Enter City to the button s OFF state BAU Append unicode text Same format as UNI Syntax BAU vt addr range button states range unicode text...

Страница 158: ...d R G B colors values RRGGBB Refer to theRGB Values for all 88 Basic Colors table on page 141 BCF Set the fill color to the specified color Only if the specified fill color is not the same as the curr...

Страница 159: ...ermines what order each layer of the button is drawn Syntax BDO vt addr range button states range 1 5 1 5 1 5 1 5 1 5 Variable variable text address range 1 4000 button states range 1 256 for multi st...

Страница 160: ...Set the number of lines removed equally from the top and bottom of a composite video signal The maximum number of lines to remove is 240 A value of 0 will display the incoming video signal unaffected...

Страница 161: ...ce address 1 4000 source state 1 256 codes BM Picture Bitmap BR Border CB Border Color CF Fill Color CT Text Color EC Text effect color EF Text effect FT Font IC Icon JB Bitmap alignment JI Icon align...

Страница 162: ...les and ID Numbers table on page 143 MI mask image Set the mask image Refer to the BMI command on page 154 for more information T text Set the text using ASCII characters empty is clear P bitmap Set t...

Страница 163: ...ement Refer to the GDI command on page 160 for more information VI video ON OFF Set the Video either ON value 1 or OFF value 0 OT feedback type Set the Feedback Output Type to one of the following Non...

Страница 164: ...put masking button Syntax BML vt addr range max length Variable variable text address range 1 4000 max length 2000 0 no max length Example SEND_COMMAND Panel BML 500 20 Sets the maximum length of the...

Страница 165: ...he button opacity The button opacity can be specified as a decimal between 0 255 where zero 0 is invisible and 255 is opaque or as a HEX code as used in the color commands by preceding the HEX code wi...

Страница 166: ...ge of 500 504 510 515 The border style is available through the TPDesign4 border style drop down list Refer to theTPD4 Border Styles by Name table on page 144 for more information BOS Set the button t...

Страница 167: ...ltiple buttons Only one variable text address can be in focus at a time Syntax BSF vt addr range selection value Variable variable text address range 1 4000 selection value Unselect 0 and select 1 Exa...

Страница 168: ...address Syntax BVP vt addr range network password Variable variable text address range 1 4000 network password 1 50 ASCII characters Example SEND_COMMAND Panel BVP 500 PCLOCK Sets the password to PCL...

Страница 169: ...e ENA Enable or disable buttons with a set variable text range Syntax ENA vt addr range command value Variable variable text address range 1 4000 command value 0 disable 1 enable Example SEND_COMMAND...

Страница 170: ...invert Variable variable text address range 1 4000 joystick axis to invert 0 3 For a bargraph 1 Invert 0 Non Invert Example SEND_COMMAND Panel GIV 500 3 Inverts the joystick axis origin to the bottom...

Страница 171: ...assign the color by Name and R G B value RRGGBB or RRGGBBAA Syntax GSC vt addr range color value Variable variable text address range 1 4000 color value Refer to theRGB Values for all 88 Basic Colors...

Страница 172: ...for General buttons 1 Off state and 2 On state new text alignment Value of 1 9 corresponds to the following locations Example SEND_COMMAND Panel JSB 500 504 510 515 1 2 1 Sets the off on state pictur...

Страница 173: ...515 1 2 1 Sets the text alignment to the upper left corner for those buttons with variable text ranges of 500 504 510 515 MBT Set the Mouse Button mode On for the virtual PC Syntax MBT pass data Varia...

Страница 174: ...nd can be found in TPD4 Syntax TEF vt addr range button states range text effect name Variable variable text address range 1 4000 button states range 1 256 for multi state buttons 0 All states for Gen...

Страница 175: ...states for General buttons 1 Off state and 2 On state unicode text Unicode HEX value Example SEND_COMMAND Panel UNI 500 1 0041 Sets the button s unicode character to A Note To send the variable text A...

Страница 176: ...Shadow 1 with outline Soft Drop Shadow 5 Medium Drop Shadow 2 with outline Soft Drop Shadow 6 Medium Drop Shadow 3 with outline Soft Drop Shadow 7 Medium Drop Shadow 4 with outline Soft Drop Shadow 8...

Страница 177: ...map Justification CUSTOM_EVENT TP 529 1006 Icon Justification CUSTOM_EVENT TP 529 1007 Font CUSTOM_EVENT TP 529 1008 Text Effect Name CUSTOM_EVENT TP 529 1009 Text Effect Color CUSTOM_EVENT TP 529 101...

Страница 178: ...m the button text length string encode button text length Button Query Commands BCB Get the current border color Syntax BCB vt addr range button states range Variable variable text address range 1 400...

Страница 179: ...information The result sent to the Master would be ButtonGet Id 529 Type 1012 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT FF8000FF TEXT LENGTH 9 BCT Get the current text color Syntax BCT vt addr range butt...

Страница 180: ...529 1 Gets the button OFF state bitmap information The result sent to the Master would be ButtonGet Id 529 Type 1002 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT Buggs png TEXT LENGTH 9 BOP Get the overall...

Страница 181: ...er information The result sent to the Master would be ButtonGet Id 529 Type 1014 Flag 0 VALUE1 1 VALUE2 22 VALUE3 0 TEXT Double Bevel Raised L TEXT LENGTH 22 BWW Get the current word wrap flag status...

Страница 182: ...e index information The result sent to the Master would be ButtonGet Id 529 Type 1007 Flag 0 VALUE1 1 VALUE2 72 VALUE3 0 TEXT TEXT LENGTH 0 ICO Get the current icon index Syntax ICO vt addr range butt...

Страница 183: ...fication information The result sent to the Master would be ButtonGet Id 529 Type 1005 Flag 0 VALUE1 1 VALUE2 5 VALUE3 0 TEXT TEXT LENGTH 0 JSI Get the current icon justification Syntax JSI vt addr ra...

Страница 184: ...aster would be ButtonGet Id 529 Type 1004 Flag 0 VALUE1 1 VALUE2 1 VALUE3 0 TEXT TEXT LENGTH 0 TEC Get the current text effect color Syntax TEC vt addr range button states range Variable variable text...

Страница 185: ...Get Id 529 Type 1008 Flag 0 VALUE1 1 VALUE2 18 VALUE3 0 TEXT Hard Drop Shadow 3 TEXT LENGTH 18 TXT Get the current text information Syntax TXT vt addr range button states range optional index Variable...

Страница 186: ...le SEND COMMAND Panel AKB Texas Enter State Pops up the Keyboard and initializes the text string Texas with prompt text Enter State AKEYB Pop up the keyboard icon and initialize the text string to tha...

Страница 187: ...text ENTER PASSWORD AKR Remove the Keyboard Keypad Remove keyboard or keypad that was displayed using AKEYB AKEYP PKEYP AKB AKP PKP EKP or TKP commands Syntax AKR Example SEND COMMAND Panel AKR Remove...

Страница 188: ...PKEYP 123456789 Pops up the Keypad and initializes the text string 123456789 in PKP Present a private keypad Pops up the keypad icon and initializes the text string to that specified Keypad displays a...

Страница 189: ...er Phone Number Pops up the Keypad and initializes the text string 999 222 1211 with prompt text Enter Phone Number TPAGEON Turn On page tracking This command turns On page tracking whereby when the p...

Страница 190: ...hanism This process sends a virtual keystroke command VKS to the Master Example 2 SEND COMMAND Panel KPS 0 Disables the keyboard passthru to the Master The following point defines how the parameters w...

Страница 191: ...wn 131 83 F1 132 84 F2 133 85 F3 134 86 F4 135 87 F5 136 88 F6 137 89 F7 138 8A F8 139 8B F9 140 8C F10 141 8D F11 142 8E F12 143 8F Num Lock 144 90 Caps Lock 145 91 Insert 146 92 Delete 147 93 Home 1...

Страница 192: ...D Main Sets the page flip password to Main PWD Set the page flip password Password level is required and must be 1 4 Syntax PWD password level page flip password Variables password level 1 4 page flip...

Страница 193: ...Force a refresh for a given resource Syntax RFR resource name Variable resource name 1 50 ASCII characters Example SEND_COMMAND Panel RFR Sports_Image Forces a refresh on Sports_Image RMF Modify an e...

Страница 194: ...he resource is downloaded again Refreshing a resource causes the button displaying that resource to refresh also The default value is 0 only download the resource once Full path to the location of the...

Страница 195: ...ol connection to a target panel you are prompted with a G4 Authentication dialog which asks you to enter the assigned password for the panel before gaining access If you are ever prompted with a VNC S...

Страница 196: ...gotiate a DHCP Address and try again My NXT BP battery pack is blinking when I check the battery life indicator A blinking battery life LED indicates that there is less than 10 power charge remaining...

Страница 197: ...protective cover acts to press on the entire LCD and makes calibration difficult because the user can t calibrate on specific crosshairs when the sheet is pressing on the whole LCD Verify that the pro...

Страница 198: ...want to work with multiple Masters open different instances of NetLinx Studio and assign each Master its own System value Example a site has an NXC ME260 64 and an NI 4000 In order to work with both u...

Страница 199: ...act Flash Cause If the G4 device already contains a large enough file subsequent downloads will take up more space than is available and could often corrupt the Compact Flash The demo file that typica...

Страница 200: ...Troubleshooting 190 7 Modero Widescreen Touch Panels...

Страница 201: ...Text Code Inputs Code Bargraph Multi State Bargraph P Display the current percentage of the bargraph derived from the Adjusted Level Value as it falls between the Range Values Display the current per...

Страница 202: ...s characters Limit the number of characters in a text area Suggest proper format with fixed characters Right to Left Required or Optional Change Force a Case Create multiple logical fields Specify ran...

Страница 203: ...ge the behavior of the field in the following way Input mask literals To define a literal character enter any character other than those shown in the above table including spaces and symbols A back sl...

Страница 204: ...ield the overflow value is added to the previous field on the chain if the overflow character was specified In the above example if the overflow flag was set the first example will place the 1 into th...

Страница 205: ...t port for http is 80 An alternative port could be specified as http www amx com 8080 company info home asp Special escape sequences The system has only a limited knowledge of URL formats in that it t...

Страница 206: ...Appendix A 196 7 Modero Widescreen Touch Panels...

Страница 207: ...all network traffic will be via the wireless network The wired network connection always takes priority As an example Imagine a panel connected to two networks A B A is the wired network and B is the...

Страница 208: ...Government documents classified as Top Secret The AES cipher is the first cipher protecting Top Secret information available to the general public CERTIFICATES CA A certificate can have many forms bu...

Страница 209: ...d network As a result of identified weaknesses in this scheme WEP was superseded by Wi Fi Protected Access WPA and then by the full IEEE 802 11i standard also known as WPA2 WPA Wi Fi Protected Access...

Страница 210: ...ty and origin authentication WPA2 implements the full standard but will not work with some older network cards Both provide good security with two significant issues either WPA or WPA2 must be enabled...

Страница 211: ...e Microsoft Sever 2003 Juniper Odyssey once called Funk Odyssey Meetinghouse AEGIS Server DeviceScape RADIUS Server Cisco Secure ACS EAP characteristics The following table outlines the differences am...

Страница 212: ...Response Identity message through the WAP to the RADIUS server providing its identity and specifying which EAP type it wants to use If the server does not support the EAP type then it sends a failure...

Страница 213: ...if any The Certificate Upload Utility recognizes the following certificate file types CER Certificate File DER Distinguished Encoding Rules PEM Privacy Enhanced Mail PFX Normal Windows generated cert...

Страница 214: ...connection remains RED after changing the communication from Ethernet to USB until the panel is rebooted Once the panel restarts the connection turns a dark green until connected to an active USB cab...

Страница 215: ...r via the USB port direct connection If using an Ethernet connection skip to step 8 6 For a USB connection select the 10 XX XX 1 IP Address which corresponds to the virtual IP Address assigned to the...

Страница 216: ...toggling the box next to the Send entry with the Type column selected as a group by clicking on the Check All radio box located at the top of the device IP Address listing 13 When you are ready to sen...

Страница 217: ...Appendix B Wireless Technology 207 Modero Touch Panels...

Страница 218: ...Appendix B Wireless Technology 208 Modero Touch Panels...

Страница 219: ...Appendix 209 7 Modero Widescreen Touch Panels...

Страница 220: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Отзывы: