Appendix B – Telnet (Terminal) Commands
113
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
Setting a Telnet Username and Password
To set a Telnet username and password:
1.
Establish a terminal connection via Telnet (see page 111).
2.
Type
Set Telnet Username
, and press Enter.
a.
The program will prompt you to enter a new Telnet username; enter a username and press Enter.
b.
The program will indicate that the username is being stored.
3.
Type
Set Telnet Password
, and press Enter.
a.
The program will prompt you to enter a password; press Enter twice to clear both the Telnet
username and password.
b.
Enter a password and press Enter.
c.
The program will prompt you to re-enter the password; re-enter the password and press Enter.
d.
The program will indicate that the password is being stored.
Telnet Commands
The Telnet commands listed in the table below can be sent directly to the Transmitter or Receiver via
a Telnet terminal session.
The default Telnet port is
23
. A value of
0
(zero) disables the Telnet server.
Telnet is enabled by default.
In the terminal program, type
Help
or a question mark (
?
) and press Enter to access the Help Menu and
display the terminal commands described in the table below
.
Telnet Commands
Command
Description
? or Help
Display the commands listed in this table.
DEVICE STATUS
Displays device status of a specified device, port, system (<D:P:S>).
Note:
Devices other than the DXLink Transmitter or Receiver itself will be ignored.
Example:
>device status 32002:1:0
Device Status
-------------
Device 32002 AMX LLC,DXLINK-HDMI-RX, 0.0.106.0 contains
7 Ports
Port 1 - Channels:255 Levels:8
MaxStringLen=64 Types=8 bit MaxCommandLen=64 Types=8 bit
The following input channels are on:None
The following output channels are on:None
Level 1=0 Supported data types=UByte,UInt
Level 2=0 Supported data types=UByte,UInt
Level 3=0 Supported data types=UByte,UInt
Level 4=0 Supported data types=UByte,UInt
Level 5=0 Supported data types=UByte,UInt
Level 6=0 Supported data types=UByte,UInt
Level 7=0 Supported data types=UByte,UInt
Level 8=0 Supported data types=UByte,UInt
>
Содержание AVB-DWP-TX-MULTI-DXLINK
Страница 6: ...Contents iv Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 12: ...Notices 6 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 38: ...Product Overview and Specifications 32 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 78: ...Network Configuration 72 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 116: ...Appendix A Upgrading the Firmware 110 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 136: ...Appendix D Cable Details and Pinout Info 130 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 140: ...Appendix E Supported Input Resolutions 134 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...
Страница 146: ...Appendix F Supported Output Resolutions 140 Instruction Manual DXLink Twisted Pair Transmitters Receiver ...