background image

  

 

ii 

 

Amphenol Network Solutions 

All rights reserved. 12.18.19 139688-3 

509.926.6000 – amphenol-ns.com 

100A Dual-Feed 

Breaker Panel

 

Installation Guide, Part Number 139688-3 

 
Copyright 2019, Amphenol Network Solutions, All rights reserved.  
 
Amphenol Network Solutions 

22425 East Appleway Ave. # 11 

Liberty Lake, WA 99019 

 

 

Amphenol Network Solutions assumes no liability from the application or use of these products. 
Amphenol Network Solutions does not convey any license under its patent rights nor the patent rights of 
others. This document and the products described herein are subject to change without notice. 
 

 

About 

 

Amphenol Network Solutions is a global innovative original equipment manufacturer that serves the data 
and communications markets. We design, manufacture, and distribute products for customers who need 
an end to end solution for network connectivity, fiber, power distribution and rack management. We 
collaborate with our customers to deliver product solutions that exceed expectations with innovative 
designs and world class quality. Amphenol Network Solutions is the industry thought leader on network 
cable management. 
 
 

 

Telect, Inc. has been a market leader in secondary DC power distribution for over 
36 years. Through our acquisition by Amphenol and our merger with All Systems 
Broadband, to become Amphenol Network Solutions, we have continued to 
deliver reliable, high-quality solutions to power, protect, and monitor today’s 
network servers and equipment. We are proud to be an Amphenol company that 
will continue to be Powered by Telect.

 

 

Technical Support  

Email: [email protected] 

Phone: 509.926.6000 

 

Содержание T009-5030 Series

Страница 1: ...100A Dual Feed Breaker Panel T009 5030XXXXXXX Installation Guide...

Страница 2: ...data and communications markets We design manufacture and distribute products for customers who need an end to end solution for network connectivity fiber power distribution and rack management We co...

Страница 3: ...mary 11 1 6 1 Normal Operation 11 1 6 2 Input Power Failure 11 1 6 3 Output Breaker Opens either being tripped or manually turned off 11 1 7 Schematic Drawing 12 1 8 Assembly Drawing 13 List of Figure...

Страница 4: ...ccessories Page 10 for ordering optional and replaceable items output breakers face plates lugs ETSI mounting kit and more Mechanical Specifications Dimensions nominal without brackets Width Height De...

Страница 5: ...vice rating 125A Maximum continuous load rating total 100A per feed Maximum output interruption device rating 20A per circuit breaker Maximum continuous output load rating 16A per circuit breaker Alar...

Страница 6: ...tion If you need assistance call Amphenol Network Solutions Technical Support at 509 926 6000 or email us at getinfo amphenol ns com Inspect equipment after unpacking and compare it to the packing lis...

Страница 7: ...unused rack position and mount panel using the four screws and lockwashers provided as shown in Figure 3 It s best to mount the panel as high as possible on the rack Tighten screws to 35 in lb 4 29 N...

Страница 8: ...to the panel is turned off 6 Make sure the input power is off 7 For input wiring wiring used as inputs to this distribution panel proceed as follows a Crimp dual hole compression lugs onto suitable co...

Страница 9: ...ress and hold ALARM RESET on front of panel for 5 seconds to verify that all LEDs are in working order 14 With one or all circuit breakers off test fuse alarm relay contacts at FUSE ALARM terminals on...

Страница 10: ...nation labels supplied to record outputs as specified by operating company standard installation procedures 23 Make sure inputs at loads are disabled by removing all power cards or all input fuses at...

Страница 11: ...so it slightly protrudes out of the front of the panel 3 While preventing the breaker from going back into the panel depress the bottom tab with the screwdriver and pull out on the breaker This starts...

Страница 12: ...eaker and check the orientation of the new breaker 12 Press the spade connector of the new breaker into the pliers held LINE connector until it is fully seated Visually inspect the connection to be su...

Страница 13: ...Amphenol Network Solutions Part No 117995 included with your panel Item Description Part Number Alarm Card Power CB LEDs with Alarm Reset 400329 Circuit Breaker1 1A long delay 129316RC 3A long delay...

Страница 14: ...osed b C to NO is open 4 POWER FAIL relay is energized so that a C to NC is closed b C to NO is open 1 6 2 Input Power Failure 1 POWER ON A or POWER ON B LED s will go off 2 POWER FAIL relay de energi...

Страница 15: ...12 Amphenol Network Solutions All rights reserved 12 18 19 139688 3 509 926 6000 amphenol ns com 100A Dual Feed Breaker Panel 1 7 Schematic Drawing Shown in alarm state Not Used Not Used...

Страница 16: ...lutions convey any license under its patent rights or the patent rights of others This document and the products described herein are subject to change without notice 1 70 1 25 23 00 58 4 22 31 56 7 1...

Отзывы: