Technical Specifications
Summary of Features
Digital Setting for various parameters with LCD display
Auto fault sensing ( AFS ) with fault contact
Built in standby amplifier changeover
RS485 interface for monitoring and remote setting
Tone and bass controls
Auto fan speed controls
Thermal, fuse, output short circuit protections
High efficiency with low current consumption
QP2250
447VA (1.7A)
10.6A
0.7A
250W
31.6V
40 Ohm
12.70 kg
14.60 kg
QP2125
294VA (1.1A)
5.9A
125W
22.3V
80 Ohm
11.60 kg
13.50 kg
QP2375
749VA (2.9A)
16.7A
375W
38.7V
27 Ohm
16.50 kg
18.00 kg
QP2500
873VA (3.3A)
19.6A
0.9A
500W
44.8V
20 Ohm
18.05 kg
19.90 kg
220 - 240V ac or 24V DC back up supply
1V / 10 K ohm; balanced via XLR female
-40 to 0 dB
70 Hz - 15 KHz @ 1 KHz +/- 3 dB
>70 dB @ 1 KHz, 1V
<0.18 %
Thermal, Short circuit, Overload, Fuse
75 Deg C
Auto temperature controlled fan speed with auto on
LCD with temp, audio level and address
RS485, 19.2 kbps
Internal Pilot Tone, Detection at 15 to 25 secs at 10 secs intervals
Standby amplifier relay activation, fault dry contact
482 x 88 x 335 mm
Power requirement
Power consumption (240V AC)
Current consumption (24V DC)
Standby current (24V DC)
Input signal
Input gain control
Rated output (100V, RMS)
4 ohm output voltage
Output impedance (max load)
Frequency response
S/N ratio
THD + N
Protections
Cut off temperature
Cooling system
Indications
Communication
Fault sensing
Fault detection response
Dimension (W x H x D)
Net Weight (kg)
Gross Weight
QP2000 | Quantum Series Power Amplifiers
PAGE 11
Remote monitoring through PMX II LAN via iPX5500 Comm. Box
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product