Parts Identification

3

4 5 6

7

9

1

10

12

11

8

Front View

2

1.  POWER SWITCH

Mains ac power switch. The unit operates with 220 - 240V ac.

2.  LCD DISPLAY

2 X 18 character LCD displaying units parameters and programming instructions.

3.  CONTROL BUTTONS

Buttons for various controls and setting up the unit.

4.  GROUND LIFT SWITCH

Switch to isolate or link signal ground to equipment body.

PAGE 2

QP2000 | Quantum Series Power Amplifiers

5.  RS485 DATA LINK

RS485 data port for parameter reading or controls from PC or external triggering panel. For PC link, a USB-RS485

converter shall be required whereas the software is available free. 

6.  AMP. FAULT CONTACT

A dry contact shall be available if the amplifier is detected as faulty. This allows activation of external changeover or

enable external notification panel.

7.  AUDIO INPUT / LINK SIGNAL 

 

8.  VENTILATION FAN

It is a variable speed temperature dependant fan with air blows from inside out. The fan can be set to auto or always

on mode. See “Setting Up the Unit” in the following sections. 

Rear View

PUBLIC ADDRESS POWER 

AMPLIFIER ● QUANTUM POWER SERIES

The amplifier accepts balanced audio signal and a link Phoenix connector is available to connect in parallel to the 

next amplifier. The output link signal is buffered.

+ 24V

- 24V

+ 24V

- 24V

100V (20 

)

70V (10 

)

45V (4 

)

COM

+ OUT

- OUT

+ IN

- IN

STANDBY CHANGOVER

SPEAKER OUTPUT

DC INPUT

FLOAT

FRAME

GROUND

GROUND LIFT

ADEQUA

TE VENTILA

TION

THIS EQUIPMENT

 REQUIRES

DO NO

BL

OCK 

VENT

QP 2500

POWER AMPLIFIER                   

500W  100V

RISK OF ELECTRICAL SHOCK

DO NOT OPEN

CAUTION

RS 485

AMP FAULT

COM

NO

A

B

Another Quality Product From

AMPERES ELECTRONICS

WARNING !

BALANCED INPUT

1V / 10K 

LINK

IN + 

Out +

GND

Out -

IN - 

INPUT

50/60 Hz

AC 220 - 240V 

MADE IN MALAYSIA

TO REDUCE THE RISK OF FIRE OR

ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

Содержание Quantum QP2125

Страница 1: ...cation product QP2000 series are available in the power range of 125 250 275 and 500W 100V line ratings with 2 hu height Control parts had been made contemporary with digital settings via front panel...

Страница 2: ...el 7 AUDIO INPUT LINK SIGNAL 8 VENTILATION FAN It is a variable speed temperature dependant fan with air blows from inside out The fan can be set to auto or always on mode See Setting Up the Unit in t...

Страница 3: ...ng of cables 11 AUDIO LINE OUTPUTS Outputs from the units are available in 100 70V line and also for 4 Ohm speakers At any one time connect only one terminal 12 STANDBY AMPLIFIER CONNECTOR QP2000 seri...

Страница 4: ...m per es O I POWER QP2500 UP DOWN 5121 ZS OVERRIDE 2 1 3 5 4 SPEAKER ZONE SELECT 6 7 8 9 10 12 11 CALL ALL a m pe re s PM1120 PAGING MIC MX2222 Mixer EP1200 E M Mic QP2000 Amplifier Duty Unit 1 Duty U...

Страница 5: ...0V 20 70V 10 45V 4 COM OUT OUT IN IN STANDBY CHANGOVER SPEAKER OUTPUT DC INPUT FLOAT FRAME GROUND GROUND LIFT ADEQUATE VENTILATION THIS EQUIPMENT REQUIRES DO NOT BLOCK VENT QP 2500 POWER AMPLIFIER 500...

Страница 6: ...T OPEN CAUTION RS 485 AMP FAULT COM NO A B Another Quality Product From AMPERES ELECTRONICS WARNING BALANCED INPUT 1V 10K LINK IN Out GND Out IN INPUT 50 60 Hz AC 220 240V MADE IN MALAYSIA TO REDUCE T...

Страница 7: ...PMENT REQUIRES DO NOT BLOCK VENT QP 2500 POWER AMPLIFIER 500W 100V RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION RS 485 AMP FAULT COM NO A B Another Quality Product From AMPERES ELECTRONICS WARNING BAL...

Страница 8: ...adjustment select 1 1 Press MENU button and an asterisk would appear Use UP and DOWN key to adjust volume level To confirm the value press MENU button Use UP DOWN button to select the next sub menu To...

Страница 9: ...n Pilot Tone of 20KHz would be generated and the outputs shall be monitored The absence of the tone shall indicate the amplifier module or the unit is faulty At faulty condition a dry contact shall be...

Страница 10: ...u 5 press MENU to enter Firmware version This menu provides information such as system firmware version and would enable the unit to reset to factory setting erasing all previously set data For resett...

Страница 11: ...1 KHz 1V 0 18 Thermal Short circuit Overload Fuse 75 Deg C Auto temperature controlled fan speed with auto on LCD with temp audio level and address RS485 19 2 kbps Internal Pilot Tone Detection at 15...

Страница 12: ...1 KHz 1V 0 18 Thermal Short circuit Overload Fuse 75 Deg C Auto temperature controlled fan speed with auto on LCD with temp audio level and address RS485 19 2 kbps Internal Pilot Tone Detection at 15...

Отзывы: