QP2000 | Quantum Series Power Amplifiers
PAGE 3
Parts Identifications ( con’t )
T
9. AC MAINS INPUT
Operating voltage is 220 to 240V ac ; 50 hertz. Use suitable fuse for replacement.
Recommended Fuse Replacements :
10. DC INPUT TERMINAL
24V DC back up supply from batteries are connected to these connectors. Use suitable cable size to avoid overheating
of cables.
11. AUDIO LINE OUTPUTS
Outputs from the units are available in 100 / 70V line and also for 4 Ohm speakers. At any one time, connect only one terminal.
12. STANDBY AMPLIFIER CONNECTOR
QP2000 series are equipped with Auto Fault Sensing feature with Standby Fault Changeover relay incorporated.
Outputs from a standby unit is connected to these terminals and connected to the next duty pack in series. Please
refer to the section “ Connecting Standby Amplifier ”.
QP2125
QP2250
QP2375
QP2500
Slow blow fuse is recommended.
5A
6.3A
6.3A
6.3A