background image

PAGE 4

QP2000 | Quantum Series Power Amplifiers

General Schematic Diagram

Note :
Changeover :

Duty amplifier with higher priority for changeover must be placed nearest to the standby unit. ie. first output 

connection from standby amplifier must be connected to this unit. 

Standby fault changeover only available at 100V line outputs. Thereby to utilise this feature, speaker 

connections must be terminated at 100V output terminals.

If the system consists of various ratings of power amplifiers, always allocate standby unit with the highest 

power rating, to avoid overloading in the event that changeover takes place.

An  example  of  application  with 

single  source  to  amplifiers,  with 

one unit being a standby unit.

For  Uninterrupted  Paging  System 

or  Matrix  application,  please 

contact us for further details.

Application  of  PC  monitoring  of 

amplifiers is optional.

2

MENU

a m pe r e s

O

I

POWER

QP2500

UP

DOWN

MENU

a m pe r e s

O

I

POWER

QP2500

UP

DOWN

MENU

a m pe r e s

O

I

POWER

QP2500

UP

DOWN

MENU

a m pe r e s

O

I

POWER

QP2500

UP

DOWN

5121

ZS

OVERRIDE

2

1

3

5

4

SPEAKER ZONE SELECT

6

7

8

9

10

12

11

CALL

ALL

a m pe re s

PM1120 PAGING MIC

MX2222 Mixer

EP1200 E/M Mic

QP2000 Amplifier

Duty Unit 1

Duty Unit 2

Duty Unit 3

Standby Unit

Zone Selector

TO SPEAKERS

USB-RS485

Converter

PC with QPM 

Software

INPUTS

line audio

zone

triggering

100V

100V

100V

100V

line

RS485

data

Optional

In  PC  monitoring,  each 

power  pack  must  be 

addressed. Up to a max of 16 

nos  of  power  packs  can  be 

monitored.

To  avoid  signal  distortion  in 

looping  the  audio,  usage  of 

signal  distributor  (DA2208)  is 

strongly recommended

PUBLIC ADDRESS POWER 

AMPLIFIER ● QUANTUM POWER SERIES

PUBLIC ADDRESS POWER 

AMPLIFIER ● QUANTUM POWER SERIES

PUBLIC ADDRESS POWER 

AMPLIFIER ● QUANTUM POWER SERIES

PUBLIC ADDRESS POWER 

AMPLIFIER ● QUANTUM POWER SERIES

EP 1200

amperes

EMERGENCY PAGING PANEL

MIC

SIREN SWITCH

SIREN

FIRE

EMERGENCY / SIREN 

ACTIVE

O

I

amperes

MX2222

POWER

OFF

SELEC

T

T

UNER

CD

CASS

OFF

MAS

T

ER

MUSIC SOURCE

SIG IN

BASS

MAX

MIN

EX

T

 INPU

T

MAX

MAX

MIN

SOURCE

MIN

SIG IN

CHIME

MIXER

T

REBLE

MAX

MIN

T

ONE C

T

RL

CH5

CH6

CH4

SIG IN

SIG IN

SIG IN

MAX

MIN

MAX

MIN

MIN

CH3

CH1

CH2

SIG IN

SIG IN

MAX

MIN

MAX

MIN

MAX

MIN

MAX

AUX

SIG IN

Содержание Quantum QP2125

Страница 1: ...cation product QP2000 series are available in the power range of 125 250 275 and 500W 100V line ratings with 2 hu height Control parts had been made contemporary with digital settings via front panel...

Страница 2: ...el 7 AUDIO INPUT LINK SIGNAL 8 VENTILATION FAN It is a variable speed temperature dependant fan with air blows from inside out The fan can be set to auto or always on mode See Setting Up the Unit in t...

Страница 3: ...ng of cables 11 AUDIO LINE OUTPUTS Outputs from the units are available in 100 70V line and also for 4 Ohm speakers At any one time connect only one terminal 12 STANDBY AMPLIFIER CONNECTOR QP2000 seri...

Страница 4: ...m per es O I POWER QP2500 UP DOWN 5121 ZS OVERRIDE 2 1 3 5 4 SPEAKER ZONE SELECT 6 7 8 9 10 12 11 CALL ALL a m pe re s PM1120 PAGING MIC MX2222 Mixer EP1200 E M Mic QP2000 Amplifier Duty Unit 1 Duty U...

Страница 5: ...0V 20 70V 10 45V 4 COM OUT OUT IN IN STANDBY CHANGOVER SPEAKER OUTPUT DC INPUT FLOAT FRAME GROUND GROUND LIFT ADEQUATE VENTILATION THIS EQUIPMENT REQUIRES DO NOT BLOCK VENT QP 2500 POWER AMPLIFIER 500...

Страница 6: ...T OPEN CAUTION RS 485 AMP FAULT COM NO A B Another Quality Product From AMPERES ELECTRONICS WARNING BALANCED INPUT 1V 10K LINK IN Out GND Out IN INPUT 50 60 Hz AC 220 240V MADE IN MALAYSIA TO REDUCE T...

Страница 7: ...PMENT REQUIRES DO NOT BLOCK VENT QP 2500 POWER AMPLIFIER 500W 100V RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION RS 485 AMP FAULT COM NO A B Another Quality Product From AMPERES ELECTRONICS WARNING BAL...

Страница 8: ...adjustment select 1 1 Press MENU button and an asterisk would appear Use UP and DOWN key to adjust volume level To confirm the value press MENU button Use UP DOWN button to select the next sub menu To...

Страница 9: ...n Pilot Tone of 20KHz would be generated and the outputs shall be monitored The absence of the tone shall indicate the amplifier module or the unit is faulty At faulty condition a dry contact shall be...

Страница 10: ...u 5 press MENU to enter Firmware version This menu provides information such as system firmware version and would enable the unit to reset to factory setting erasing all previously set data For resett...

Страница 11: ...1 KHz 1V 0 18 Thermal Short circuit Overload Fuse 75 Deg C Auto temperature controlled fan speed with auto on LCD with temp audio level and address RS485 19 2 kbps Internal Pilot Tone Detection at 15...

Страница 12: ...1 KHz 1V 0 18 Thermal Short circuit Overload Fuse 75 Deg C Auto temperature controlled fan speed with auto on LCD with temp audio level and address RS485 19 2 kbps Internal Pilot Tone Detection at 15...

Отзывы: