EDFA-R 

Erbium Doped Fiber Amplifier with 
Redundant Power Supplies 

Product User Manual 

 

Offices 

Australia, Melbourne 

Tel: +61-3-8561-1400 

China, Beijing 

Tel: +86-10-5791-0655 

Americas 

Tel: +1-888-339-8805 

EMEA, Netherlands 

Tel: +31-36-536-8011

 

Email: [email protected] 

Website: www.pbnglobal.com 

 

©2015 Pacific Broadband Networks. All rights reserved.

 

Summary of Contents for EDFA-R

Page 1: ...roduct User Manual Offices Australia Melbourne Tel 61 3 8561 1400 China Beijing Tel 86 10 5791 0655 Americas Tel 1 888 339 8805 EMEA Netherlands Tel 31 36 536 8011 Email support pbnglobal com Website www pbnglobal com 2015 Pacific Broadband Networks All rights reserved ...

Page 2: ...EDFA R Erbium Doped Fiber Amplifier with Redundant Power Supplies Product User Manual Release Date October 9 2015 Document version V1c Document reference PBN EDFA R Manual V1c Released 9 Oct 15 Document status Released Prepared by Pacific Broadband Networks Prepared for Product Users ...

Page 3: ...nt system 13 3 3 1 Standard Compliant 13 3 3 2 Main features 13 3 3 3 MIB File 14 3 4 RS 232 monitoring and terminal management with RS232 communications 14 3 4 1 Hardware condition 14 3 4 2 Terminal management 16 3 5 TELNET management and SNMP network management 17 3 5 1 Hardware Requirements 17 3 5 2 Network Configuration 18 3 5 3 TELNET operation 19 3 6 Laser safety 20 3 6 1 Laser safety precau...

Page 4: ...mp Laser State 25 4 3 5 Modify the equipment alarm status 25 4 3 6 Change the output power 25 4 3 7 Select the COM port 25 4 3 8 Resetting the device 26 4 3 9 View the device s serial number 26 4 3 10 Network Parameter Configuration Operation 26 4 3 11 LCD display translation table 27 4 4 The definition of the alarm threshold 28 5 Product Warranty 31 ...

Page 5: ... damage your eyes or skin Avoid vibration and collision The device contains precision optical components that can be damaged Please handle carefully and ensure the device is properly grounded The device is sensitive to static electricity Special notice for the optical fiber interface 1 The optical fiber interface must be clean 2 When setting up the device insert the output fiber first Then insert ...

Page 6: ... power consumption by up to 30 When the case temperature is over 45 degrees Celsius a fan will start and continue to operate until the temperature is under 40 degrees Celsius The technology ensures the thermal stability of the system and increase the fan s lifespan It has an intelligent network management system The device can be controlled through the Ethernet interface the RS 485 interface and R...

Page 7: ...r port 4 ports total 250 mw 24 dBm 1RU 4 22 4 22 dBm 22 dBm per port 4 ports total 634 mw 28 dBm 1RU 5 16 5 16 dBm 16 dBm per port 5 ports total 200 mw 23 dBm 1RU 6 16 6 16 dBm 16 dBm per port 6 ports total 240 mw 24 dBm 1RU 2RU Height1 8 15 8 15 dBm 15 dBm per port 8 ports total 256 mw 24 dBm 2RU 8 16 8 16 dBm 16 dBm per port 8 ports total 320 mw 25 dBm 2RU 8 22 8 22 dBm 22 dBm per port 8 ports t...

Page 8: ...X Network Management 0 None 1 SNMP Y Power Supply Options AC 90 265 Vac 50 60 Hz DC 36 72 Vdc 1A Single mains power supply 220Vac 2A Dual mains power supplies 220Vac 1D Single mains power supply 48 Vdc 2D Dual mains power supplies 48 Vdc AD With two mains power supplies of 220Vac and 48 Vdc Z Power Cable EU Power Cable for Europe not for use in UK CN Power Cable for China CH Power Cable for Switze...

Page 9: ...EDFA R Product User Manual Pacific Broadband Networks 9 October 2015 Page 9 of 32 1 4 Mechanical Figures Case Size 483 380 44 mm MAX Net weight 6 1 kg ...

Page 10: ...ber 2015 Pacific Broadband Networks 2 Operating principle 2 1 The architecture of the equipment Input Signal Output Signal Input PD Output PD TAP TAP Isolator Isolator Er Yb Double Clading fiber Combiner Multimode Pump Multimode Pump Amplifier Unit ...

Page 11: ...s RL 45 dB Polarization Dependent Gain PDG 0 3 dB PMD PMD 0 5 ps Optical connector SC APC E2000 APC FC APC LC APC Electrical Performance Parameters Symbol Min Typ Max Unit Power Supply 4 Vps 85 170 220 132 264 VAC Power Consumption 5 P 18 W General Parameters Symbol Min Typ Max Unit Operation Temperature Tw 5 60 Storage Temperature Ts 40 80 Humidity no condensation Pi 10 90 Dimensions H x W x D 44...

Page 12: ... L 保护地 电源 电源 保护地 电源 FGND E 电源 保护地 电源 48V FGND PGND L Live N Neutral E Earth 保护地 电源 保护地 电源 N E L N PIN1 RED PIN2 YELLOW GREEN PIN3 BLUE L 保护地 电源 电源 保护地 电源 FGND E 电源 保护地 电源 48V FGND PGND L Live N Neutral E Earth 保护地 电源 保护地 电源 N E L N PIN1 RED PIN2 YELLOW GREEN PIN3 BLUE 220VAC Interface Definition 220 VAC Interface L 保护地 电源 电源 保护地 电源 FGND E 电源 保护地 电源 48V FGND PGND L Live N Neutral E Earth 保护地 电源 保护地...

Page 13: ...J45 Ethernet interface hardware feature RJ45 Ethernet interface specifications Table 3 2 RJ45 Ethernet interface specifications Interface type RJ45 Speed rate 10 Mbit s 3 3 SNMP AGENT network management system The SNMPv1 and SNMPv2 are supported by the firmware It can be accessed by the standard SNMP network management tools Through network management software detailed parameters can be viewed inc...

Page 14: ...PBN s technical support for the full list of MIB parameters 3 4 RS 232 monitoring and terminal management with RS232 communications The equipment can be accessed from a PC by a female to female DB 9 connection and the communication distance must not exceed 12 m 3 4 1 Hardware condition Item Parameter Quantity RS232 cross line DB 9 female 1 PC serial port software with DB 9 male COM port Windows sy...

Page 15: ...EDFA R Product User Manual Pacific Broadband Networks 9 October 2015 Page 15 of 32 Figure 3 1 standard MIB tree ...

Page 16: ...ion layout 3 4 2 Terminal management Connect the equipment and PC by a serial cable and power on the equipment and then start the terminal software according to the parameters of the selected serial port 9600 bps 8 bit data 1 bit stop parity and flow control off Once a terminal connection is successfully established please input the user name admin and the password 12345 After successfully logging...

Page 17: ...p N A Displays the help interface N A Displays the help interface ver N A Displays the equipment version set Ip IP Address Used to set an IP address show N A Displays the equipment configuration information set logo xxxxxx Set a string of text to act as a logo The content of logo text must be less than 20 characters and quotation marks must be used 3 5 TELNET management and SNMP network management...

Page 18: ...Direct line Two heads the center line of the same order such as the two are T568B stander Figure 3 3 Network line connection figure 3 5 2 Network Configuration The steps for directly connecting the equipment with a PC 1 Set the IP address through the front panel 2 Connect the RJ 45 port to a PC Ethernet port using a crossover Ethernet cable The steps for connecting equipment with a PC through a ne...

Page 19: ... R supports TELNET management To access the EDFA R s TELNET server from Windows open a DOS command prompt and type telnet 192 168 25 168 Press the Enter key and the computer should connect with the equipment In this example 192 168 25 168 is the IP address of the equipment 2 After successfully connecting the user name and password is required ...

Page 20: ...h as a computer crash close the command window directly by clicking X in the top right of the window to close it Reconnecting to the equipment immediately will fail You must wait 5 minutes for the previous session to timeout If the EDFA R restarts abnormally but the TELNET command line window was not closed you must force close the window and wait for 5 minutes to reconnect 3 6 Laser safety This p...

Page 21: ...nvas to prevent damage from moisture or condensation 2 Stack the products in manner that prevents them from moving during shipment 3 It is recommended to not ship the equipment with flammable explosive or corrosive products 4 Place equipment must be carefully handled Never turn the equipment upside down 3 7 3 Storage 1 When storing the equipment place it in its original packaging 2 The environment...

Page 22: ...een color indicates a normal state Power 2 Power 2 indicated the status of Power Module 2 Red and yellow colors indicate a problem A green color indicates a normal state Alarm General warning indicator This LED Is used to indicate non optical problems with the EDFA R unit Red and yellow colors indicate a problem A green color indicates a normal state Signal Optical activity indicator Red and yello...

Page 23: ...the unit on After powering the device the screen shows the company and model information After 3 seconds the device parameter menu will be showed 4 3 1 EDFA R s Front Display Main Menu The display menu will change when the key is pressed Notice If there is one pump laser the menu will display the pump state information if two pump lasers exist all pump information will be displayed ...

Page 24: ...repowered or reset 4 3 3 Modify the working mode of the equipment Work Mode APC OK Are you sure ESC NO OK YES ESC Work Mode AGC Are you sure ESC NO OK YES Work Mode ACC Work Mode APC OK OK OK Work Mode APC OK Are you sure ESC NO OK YES ESC Work Mode AGC Are you sure ESC NO OK YES Work Mode ACC Work Mode APC OK OK OK Notice The equipment is already calibrated There are no calibration settings for t...

Page 25: ...X XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw OK Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw ESC ESC ESC OK Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw Output Power XX XXdBm XX XXmw OK Output Power XX XXdBm XX XXmw Out...

Page 26: ...e s serial number OK Serial NO XXXXX XXXXX Basic State More detail Basic State More detail ESC OK Serial NO XXXXX XXXXX Basic State More detail Basic State More detail ESC 4 3 10 Network Parameter Configuration Operation Modify IP address Select the EDFA R IP Address menu then press the OK key The next menu appears and there will be flashing cursor which can use the up or down across to select a n...

Page 27: ...g time Working Temp Operating temperature 5V Power Voltage of the equipment EDFA R MAC Address MAC address Module TEMP Module temperature EDFA R IP Address IP address In Power input power Gateway IP Address IP Gateway address Out Power output power Subnet Mask IP The subnet mask Pump 1 TEMP Pump 1 temperature EDFA R PORT Number Reserved for factory Pump 1 Current Pump 1 current Module TEMP MAX the...

Page 28: ...Basic information item Pump 1 Power Min the minimum power of pump 1 s alarm threshold Fan speed monitor 4 4 The definition of the alarm threshold When the alarm values are beyond or below the threshold set the corresponding alarms will be indicated Corresponding LEDs are change according to the type of the alarm In addition network management software can also show alarms There are four level alar...

Page 29: ...al temperature scope is 5 to 70 degress Celsius the Hi Hi threshold is 70 and the hysteresis value is 1 If the temperature of the equipment is up to 75 degrees Celsius then the Hi Hi temperature alarm indicates the temperature has exceeded the Hi Hi threshold of 70 degrees Celsius The following table shows the various parameter ranges of the device The parameters may vary depending on the applicat...

Page 30: ...ks Voltage 2 V 6 5 5 4 5 4 0 1 Current 1 A 7 5 1 2 0 1 Current 1 A 7 5 1 2 0 1 Equipment temperature degrees Celsius 80 75 5 10 0 1 pump temperature unit degrees Celsius 35 30 20 15 0 1 cooling current unit mA 3000 2500 2500 3000 0 1 pump working current unit mA 1500 1400 10 5 0 1 ...

Page 31: ...er conditions outside manufacturer s specifications The warranty does not cover the following 1 Products purchased from someone other than an authorized Pacific Broadband Networks dealer 2 Damage caused by accident negligence misuse abuse improper operation or failure to operate the equipment within the manufacturer s specifications 3 Damage caused by fluctuation in electrical current lightning po...

Page 32: ...Tel 61 3 8561 1400 China Beijing Tel 86 10 5791 0655 Americas Florida Tel 1 888 339 8805 EMEA Netherlands Tel 31 36 536 8011 Email support pbnglobal com Website www pbnglobal com 2015 Pacific Broadband Networks All rights reserved ...