4.6.6
Set Tag Name 1
1.
To modify ‘TN1’ press the
key to enter
2.
Use the
key to scroll through the alpha-numerals
3.
Use the
key to move the cursor across to the next digit
4.
To save, use the
key
5.
To escape, use the
key
4.6.7
Set Tag Name 2
1.
To modify ‘TN2’ press the
key to enter
2.
Use the
key to scroll through the alpha-numerals
3.
Use the
key to move the cursor across to the next digit
4.
To save, use the
key
5.
To escape, use the
key
4.6.8
Change Configuration Password
1.
To modify ‘Change Pass’ press the
key to enter
2.
Use the
key to scroll through the numbers
3.
To save, use the
key
4.
To escape, use the
key
4.6.9
Change Fault Clear Setting
1.
To modify ‘Change FLT CLR’ press the
key to enter
2.
Use the
key to toggle between Enabled and DIsabled
3.
To save, use the
key
4.
To escape, use the
key
4.7
Calibration Menu
4.7.1
To Enter the Calibration Menu:
1.
From the Monitoring Screen, press the
key twice to scroll up to level 6 ‘Calibration View and Modify’
2.
Press the
key to enter into the ‘Do you want to Continue?’ screen
3.
If YES, press the
key to gain access, if NO, press use the
key to escape
4.
On the ’Enter Password’ screen, use the
key to scroll through the numbers
5.
Then use the
key to move the cursor to the next digit
6.
Once the password has been entered, press the
key to access a second password entry screen
7.
Repeat the above steps to enter the password. Press the
to enter the ‘Calibration Menu’
To view and modify the Calibration settings use the following procedure. There are eight Levels in the Calibration
Menu. These levels allow the programmer to calibrate the four channels, three outputs and the supply voltage.
To perform a supply voltage calibration, it will be necessary to connect a
variable 10-16 Vdc power source.
Содержание gasguard
Страница 46: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 45 10 2 Modbus Memory Map Part 2 ...
Страница 47: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 46 ...
Страница 49: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 48 A2 Top Level Functional Block Diagram ...
Страница 50: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 49 A3 Input Channel Functional Block Diagram ...
Страница 51: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 50 A4 Zoning Functional Block Diagram ...
Страница 52: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 51 A5 Relay Functional Block Diagram ...
Страница 53: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 52 A6 Current Follower Outputs Performance Graph ...
Страница 62: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 61 B2 Main Menu Flowchart ...
Страница 63: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 62 B3 Calibration Flowchart ...
Страница 64: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 63 B4 Configuration Flowchart ...
Страница 65: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 64 Configuration Flowchart con t ...
Страница 66: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 65 Configuration Flowchart con t ...
Страница 74: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 73 Appendix C Approvals ...
Страница 75: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 74 ...
Страница 76: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 75 ...
Страница 77: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 76 ...
Страница 78: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 77 ...
Страница 79: ...GASGUARD IS CONTROLLER Issue R2 Date 26 09 2011 CRN 7502 Page 78 ...