B. SPECIFICATIONS OF CONCRETE
(See Fig. 4).
Specifications of concrete must be adhered to the specification as following.
Failure to do so may result in lift and/or vehicle falling.
1. Concrete must be thickness 100mm minimum and without reinforcing steel
bars, and must be dried completely before the installation.
2. Concrete must be in good condition and must be of test strength 3,000psi
(210kg/cm²) minimum.
3. Floors must be level and no cracks.
Fig. 4
C. POWER SUPPLY
The electrical source must be 2HP minimum. The source cable size must be 2.5mm²
and in good condition of contacting with floor.
III
.
STEPS OF INSTALLATION
A. Location of Installation
Check and insure the installation location (concrete, layout, space size etc.) is
suitable for lift installation.
B.
Use a carpenter’s chalk line to establish installation layout of baseplate
(See Fig. 5)
.
Fig. 5
Chalk line
66
Concrete intensity must be
3000psi (210kg/cm²) minimum
136-1/4
”
Содержание 209X
Страница 1: ...TWO POST LIFT Model BP 9X...
Страница 4: ...2 MODEL 209X SPECIFICATIONS 3 1 2 12 1 2...
Страница 5: ...3 Fig 2 For Model 209X 100 3 4 28 50 5 8 28 50 5 8...
Страница 12: ...10 H Lift the carriages up by hand and make them be locked at the same level See Fig 17 Fig 17...
Страница 14: ...12 K Install hydraulic power unit and oil hose assy See Fig 20 Fig 19 71 68 71A 71 69A 70 71 69 71...
Страница 19: ...17 Terminal 3 of control button is connected with terminals L1of AC contactor Fig 27 Single phase...
Страница 20: ...18 IV EXPLODED VIEW Model BP 9X Fig 28 Car in direction...
Страница 21: ...19 Cylinders MANUAL POWER UNIT 220V 60Hz 1Phase Fig 30 Fig 29...