Page
14 of 35
If an information window appears, close it with OK.
Then tap their data, then change
MASTER PIN
and PIN-code. It the factory default
master PIN is queried first 12345, then opens a window in which you can assign a
name and a new PIN.
Then, you go through all of the settings from top to bottom and make the necessary
settings.
Selection of the security system
Here you can activate the immediate alarm when the first sensor triggering (traditional
alarm system) as an alternative. The control unit starts then immediately all alert levels
(immediate turn of the alarm loudspeaker, siren, discontinuation of call, etc.). The
described and recommended multistage alarm sequence is set at the factory.
Here you get done even a brief outline of what procedures in case of an alarm:
Multi-level alarm process
1. Sensor = alarm
1) 2 photos are shot and sent via e-mail
2) SMS and mail with content "pre-alarm" will be sent
3) Alarm video with sound is played
4) Photos are taken every 5 seconds and uploaded to the server (this is in
Germany)
If no second sensor is triggered within 90 seconds or the tablet is touched, the tablet
will turn back on.