Table A-4
SCPI Commands for Calibration
Function
SCPI Command
Description
Parameter and
Range
Query
Restore
Factory
Calibration
[:]CALibration[<channel>]:RESTore
Restores the calibration to
the factory defaults.
N/A
N/A
Restore
Default
Calibration
[:]CALibration[<channel>]:DEFault
Restores the default
calibration for all variables.
(Unit gain and zero offset).
N/A
No
Calibrate
OVP
protection.
[:]CALibration[<channel>][:VOLTage]
:PROTection[:OVER]
Calibrate the over voltage
protection.
<OVP Voltage Set
in Volts>
No
Enter Output
Voltage Data
[:]CALibration[<channel>]:OUTPut
:VOLTage
Sets the voltage output
calibration level.
<Voltage set in
volts>
No
Enter Output
Current Data
[:]CALibration[<channel>]:OUTPut
:CURRent
Sets the current output
calibration level
<Current set in
amps>
No
Calibrate the
Voltage
controlled
Non Isolated
Voltage APG
feature
[:]CALibration[<channel>]:MONitor
[:VOLTage]
Calibrate the voltage
monitor signal system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Calibrate the
Voltage
controlled
Isolated
Voltage APG
feature
[:]CALibration[<channel>]:MONitor
[:VOLTage]:ISOLated
Calibrate the isolated
voltage monitor signal
system.
? | <NR1> |
<nothing for
interactive mode>
Yes
Содержание Soresen XTR 100-8.5
Страница 2: ......
Страница 16: ...xiv ...
Страница 28: ...1 8 ...
Страница 50: ...Local Operation 3 8 M370185 01 Figure 3 3 Front Panel Menu System ...
Страница 93: ...Using Multiple Power Supplies M370185 01 3 51 3 ...
Страница 94: ...Local Operation 3 52 M370185 01 ...
Страница 128: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370185 01 ...
Страница 198: ...Remote Operation 5 70 M370185 01 ...
Страница 261: ...SCPI Command Tree M370185 01 A 35 A ...
Страница 262: ...A 36 ...
Страница 279: ...Index M370185 01 IX 3 described 3 7 3 36 number available 3 36 stored values 3 36 ...
Страница 280: ...IX 4 ...