Sorensen SGI Series
Operation
M550221-01 Rev U
3-35
screen). Use the NavPad to scroll down to Home Menu
Page 2 (there will be two inter-screen navigation arrows,
one at the top and one at the bottom of the screen). Press
F3, which jumps to the Language Menu, and then use the
NavPad to scroll to the user's native language.
3.8.10
Info
The Supply Information screen shows the date that the unit
was last calibrated, Model Number and Serial Number of
the unit, and version of the software. To access this screen,
from Home Menu Page 2 press F4.
3.8.11
Remote
Remote, F1, provides screens for either the Ethernet option
or the GPIB option, described in the following subsections.
E
THERNET
The Ethernet Remote Menu displays the Ethernet MAC
address of the power supply, which cannot be edited.
Access the menu from Home Menu Page 3, F1 key. This
menu also displays in the IP IN USE: line, the IP address
presently in use from either a static IP setting or from the
DHCP server, depending on how assigned. The Baud Rate
is editable via the NavPad; changing it here changes the
rear panel RS-232 SCPI baud rate. The initial factory setting
is 19200.
LXI
The LXI submenu (F3 from the Remote Menu) displays
two settings required by the LXI requirements.
PING Response:
enables or disables the power supply’s
response to a ping packet sent from a remote Ethernet host. To
change the setting to either ENABLED or DISABLED, move the
editing arrows to the PING Response: line by pressing NavPad
left/right, and then change the setting by pressing NavPad
up/down. Press F1 to Cancel the change and return to the
Remote Menu screen, or press F4 to Save the changed setting.
Identification:
controls the LAN LED on the power supply’s
rear panel. ENABLED causes the LAN LED to flash for visual
identification. DISABLED causes the LAN LED to be steady-lit
to indicated the power supply’s connected status. To change
the setting, move the editing arrows to the Identification field by
pressing NavPad left/right, and then change the setting by
pressing NavPad up/down. Press F1 to Cancel the change and
Содержание Sorensen SGI Series
Страница 1: ...M550221 01 Rev U www programmablepower com SGI Series DC Power Supplies Operation Manual...
Страница 2: ......
Страница 34: ...Installation Sorensen SGI Series 2 12 M550221 01 Rev U Figure 2 2 Installation Drawing 3U Models 10V 30V...
Страница 35: ...Sorensen SGI Series Installation M550221 01 Rev U 2 13 Figure 2 3 Installation Drawing 3U Models 40V 600V...
Страница 36: ...Installation Sorensen SGI Series 2 14 M550221 01 Rev U Figure 2 4 Installation Drawing 3U Models 800V and 1000V...
Страница 37: ...Sorensen SGI Series Installation M550221 01 Rev U 2 15 Figure 2 5 Installation Drawing 6U Models 20kW 30kW...
Страница 38: ...Installation Sorensen SGI Series 2 16 M550221 01 Rev U Figure 2 6 Rear Panel Standard 3U Models 10V 30V...
Страница 39: ...Sorensen SGI Series Installation M550221 01 Rev U 2 17 Figure 2 7 Rear Panel GPIB Option 3U Models 10V 30V...
Страница 40: ...Installation Sorensen SGI Series 2 18 M550221 01 Rev U Figure 2 8 Rear Panel Ethernet Option 3U Models 10V 30V...
Страница 41: ...Sorensen SGI Series Installation M550221 01 Rev U 2 19 Figure 2 9 Rear Panel Standard 3U Models 40V 600V...
Страница 42: ...Installation Sorensen SGI Series 2 20 M550221 01 Rev U Figure 2 10 Rear Panel GPIB Option 3U Models 40V 600V...
Страница 44: ...Installation Sorensen SGI Series 2 22 M550221 01 Rev U Figure 2 12 Rear Panel Standard 6U Models 20kW 30 kW...
Страница 45: ...Sorensen SGI Series Installation M550221 01 Rev U 2 23 Figure 2 13 Rear Panel GPIB Option 6U Models 20kW 30 kW...
Страница 48: ...Installation Sorensen SGI Series 2 26 M550221 01 Rev U This page intentionally left blank...
Страница 103: ...Sorensen SGI Series Operation M550221 01 Rev U 3 55 Figure 3 26 Parallel Connection and Remote Sense...
Страница 116: ...Maintenance Sorensen SGI Series 5 4 M550221 01 Rev U This page intentionally left blank...
Страница 120: ...Index Sorensen SGI Series Index 4 M550221 01 Rev U This page intentionally left blank...