Sorensen SGI Series
Overview
M550221-01 Rev U
1-7
1.2.3
SGI Series Voltage and Current Specifications
The following tables present the specifications for rated voltage and current, and ripple/noise for
the 10V-1000V models.
Rated
Voltage,
VDC
Rated Current, ADC
Ripple/
Noise**
RMS,
mV
Ripple/
Noise
*
PK
–PK,
mV
4 kW
5 kW
8 kW
10 kW
12 kW
15 kW
0-10
††
0-400
N/A
0-800
N/A
0-1200
N/A
20
50
0-15
††
0-267
N/A
0-534
N/A
0-801
N/A
20
50
0-20
††
N/A
0-250
N/A
0-500
N/A
0-750
20
60
0-30
††
N/A
0-167
N/A
0-334
N/A
0-501
20
60
Rated
Voltage,
VDC
Rated Current, ADC
Ripple/
Noise**
RMS,
mV
Ripple/
Noise
*
PK
–PK,
mV
5 kW
10 kW
15 kW
20 kW
25 kW
30 kW
0-40
0-125
0-250
0-375
0-500
†
0-625
†
0-750
†
20
75
0-50
0-100
0-200
0-300
0-400
†
0-500
†
0-600
†
20
75
0-60
0-83
0-167
0-250
0-333
0-417
0-500
20
75
0-80
0-63
0-125
0-188
0-250
0-313
0-375
20
100
0-100
0-50
0-100
0-150
0-200
0-250
0-300
20
100
0-160
0-31
0-63
0-94
0-125
0-156
0-188
25
150
0-200
0-25
0-50
0-75
0-100
0-125
0-150
25
175
0-250
0-20
0-40
0-60
0-80
0-100
0-120
30
200
0-330
0-15
0-30
0-45
0-61
0-76
0-91
30
200
0-400
0-12
0-25
0-38
0-50
0-63A
0-75
30
300
0-500
0-10
0-20
0-30
0-40
0-50
0-60
50
350
0-600
0-8
0-17
0-25
0-33
0-42
0-50
60
350
0-800
0-6.2
0-12.5
0-18.7
0-25
†
0-31.2
†
0-37.5
†
80
500
0-1000
0-5
0-10
0-15
0-20
†
0-25
†
0-30
†
100
650
*
PK-PK ripple/noise, over 20 Hz to 20 MHz bandwidth, is measured across a 1 µF capacitor at
the end of a 6’ load cable with the supply operating at full load and nominal AC line voltage.
**
RMS ripple/noise, over 20 Hz to 300 kHz bandwidth, is measured directly across the output
terminals with the supply operating at full load and nominal AC input line voltage.
†
Power level not available in 6U models, but could be produced with paralleled 3U units;
up to
75 kW could be produced by paralleling up to five power supplies. Paralleling will increase
ripple/noise.
††
Models from 10V-30V are not available in 6U chassis.
Содержание Sorensen SGI Series
Страница 1: ...M550221 01 Rev U www programmablepower com SGI Series DC Power Supplies Operation Manual...
Страница 2: ......
Страница 34: ...Installation Sorensen SGI Series 2 12 M550221 01 Rev U Figure 2 2 Installation Drawing 3U Models 10V 30V...
Страница 35: ...Sorensen SGI Series Installation M550221 01 Rev U 2 13 Figure 2 3 Installation Drawing 3U Models 40V 600V...
Страница 36: ...Installation Sorensen SGI Series 2 14 M550221 01 Rev U Figure 2 4 Installation Drawing 3U Models 800V and 1000V...
Страница 37: ...Sorensen SGI Series Installation M550221 01 Rev U 2 15 Figure 2 5 Installation Drawing 6U Models 20kW 30kW...
Страница 38: ...Installation Sorensen SGI Series 2 16 M550221 01 Rev U Figure 2 6 Rear Panel Standard 3U Models 10V 30V...
Страница 39: ...Sorensen SGI Series Installation M550221 01 Rev U 2 17 Figure 2 7 Rear Panel GPIB Option 3U Models 10V 30V...
Страница 40: ...Installation Sorensen SGI Series 2 18 M550221 01 Rev U Figure 2 8 Rear Panel Ethernet Option 3U Models 10V 30V...
Страница 41: ...Sorensen SGI Series Installation M550221 01 Rev U 2 19 Figure 2 9 Rear Panel Standard 3U Models 40V 600V...
Страница 42: ...Installation Sorensen SGI Series 2 20 M550221 01 Rev U Figure 2 10 Rear Panel GPIB Option 3U Models 40V 600V...
Страница 44: ...Installation Sorensen SGI Series 2 22 M550221 01 Rev U Figure 2 12 Rear Panel Standard 6U Models 20kW 30 kW...
Страница 45: ...Sorensen SGI Series Installation M550221 01 Rev U 2 23 Figure 2 13 Rear Panel GPIB Option 6U Models 20kW 30 kW...
Страница 48: ...Installation Sorensen SGI Series 2 26 M550221 01 Rev U This page intentionally left blank...
Страница 103: ...Sorensen SGI Series Operation M550221 01 Rev U 3 55 Figure 3 26 Parallel Connection and Remote Sense...
Страница 116: ...Maintenance Sorensen SGI Series 5 4 M550221 01 Rev U This page intentionally left blank...
Страница 120: ...Index Sorensen SGI Series Index 4 M550221 01 Rev U This page intentionally left blank...