Constant-Current Mode Operation
In Constant-Current mode operation, the output current is regulated at the
selected value while the output voltage varies with the load requirements. The
current could be programmed either through the front panel or by the remote
analog current programming input; see Section 3.10. To verify operation in
Constant-Current mode, follow these steps:
1. If the output had been previously energized, allow 5 minutes for the
output capacitors to discharge. Connect a high current DC ammeter
across the rear panel positive and negative output terminals, observing
the correct polarity. Select wire leads of sufficient current carrying
capacity and an ammeter range compatible with the units maximum rated
output current.
Note:
Verification that the supply could source rated output current,
without measuring the current with an ammeter, but using only the front
panel meter, could be performed by shorting the output terminals
together.
2. Turn on the power supply.
3. If the default power-on state had been previously configured to be OFF,
when the supply reaches the Home menu Page 1, enable the
output by pressing “Output On/Off”.
4. Enter the Default Programming menu by pressing either of the
voltage, current, or overvoltage front panel keys:
5. Program the Voltage to 10% of rated output (this programs the voltage
above zero to enable supplying output voltage while in the constant-
current mode). See Section 3.8.1 for more details on programming.
6. Navigate to Current programming. With the Editing Arrow adjacent to
“Set Curr”, press and hold the NavPad up arrow and observe both the
front panel current display and the output of the DC ammeter begin to
accelerate up. The output current should increase from 0 A to the
maximum rated current of the supply. The front panel display and DC
ammeter readings should track within the accuracies of the meter and the
front panel display.
7. Verify the front panel Constant Current Mode indicator is on.
8. Program the Voltage and Current back to zero.
9. Turn the power supply off.
10. Allow 5 minutes for the output capacitors to discharge and disconnect the
ammeter or short from the output terminals.
Содержание Sorensen SGI Series
Страница 1: ...M550221 01 Rev U www programmablepower com SGI Series DC Power Supplies Operation Manual...
Страница 2: ......
Страница 34: ...Installation Sorensen SGI Series 2 12 M550221 01 Rev U Figure 2 2 Installation Drawing 3U Models 10V 30V...
Страница 35: ...Sorensen SGI Series Installation M550221 01 Rev U 2 13 Figure 2 3 Installation Drawing 3U Models 40V 600V...
Страница 36: ...Installation Sorensen SGI Series 2 14 M550221 01 Rev U Figure 2 4 Installation Drawing 3U Models 800V and 1000V...
Страница 37: ...Sorensen SGI Series Installation M550221 01 Rev U 2 15 Figure 2 5 Installation Drawing 6U Models 20kW 30kW...
Страница 38: ...Installation Sorensen SGI Series 2 16 M550221 01 Rev U Figure 2 6 Rear Panel Standard 3U Models 10V 30V...
Страница 39: ...Sorensen SGI Series Installation M550221 01 Rev U 2 17 Figure 2 7 Rear Panel GPIB Option 3U Models 10V 30V...
Страница 40: ...Installation Sorensen SGI Series 2 18 M550221 01 Rev U Figure 2 8 Rear Panel Ethernet Option 3U Models 10V 30V...
Страница 41: ...Sorensen SGI Series Installation M550221 01 Rev U 2 19 Figure 2 9 Rear Panel Standard 3U Models 40V 600V...
Страница 42: ...Installation Sorensen SGI Series 2 20 M550221 01 Rev U Figure 2 10 Rear Panel GPIB Option 3U Models 40V 600V...
Страница 44: ...Installation Sorensen SGI Series 2 22 M550221 01 Rev U Figure 2 12 Rear Panel Standard 6U Models 20kW 30 kW...
Страница 45: ...Sorensen SGI Series Installation M550221 01 Rev U 2 23 Figure 2 13 Rear Panel GPIB Option 6U Models 20kW 30 kW...
Страница 48: ...Installation Sorensen SGI Series 2 26 M550221 01 Rev U This page intentionally left blank...
Страница 103: ...Sorensen SGI Series Operation M550221 01 Rev U 3 55 Figure 3 26 Parallel Connection and Remote Sense...
Страница 116: ...Maintenance Sorensen SGI Series 5 4 M550221 01 Rev U This page intentionally left blank...
Страница 120: ...Index Sorensen SGI Series Index 4 M550221 01 Rev U This page intentionally left blank...