Section 1. Features and Specifications
Additional Electrical Specifications
Additional Electrical Specifications
Voltage Mode Transient Response
(Time for the output voltage to
recover to ±50 mV band for 50%
load change in the range of 25% to
100% of the rated load.)
Time delay from power on until
output stable
<500
s
1.5 s maximum
Input Conditions
Rated AC Input Voltage
120 Vac standard; 230/240 Vac AC200 option
Maximum AC Input Power
625 VA
Operational AC Input Voltage Range Single Unit: 104
–
127 Vac at 6 Arms
Dual Unit: 104
–
127 Vac at 12 Arms
AC 200 Option
Single Unit: 200
–
250 Vac at 3 Arms
Dual Unit: 200
–
250 Vac at 6 Arms
Maximum Input Current (per unit) at 6 A maximum at 104 Vac
nominal power line impedances
Input Frequency Range
47
–
63 Hz