Section 1. Features and Specifications
Electrical Characteristics
Electrical Characteristics
Switching Frequency
100 kHz (nominal)
Output Hold-up Time
25 ms at nominal line
Maximum Voltage Differential from
output to safety ground
±400 Vdc
Insulation Resistance
Input to chassis: >120
M
Output to chassis:
>120 M
Isolation Voltage
(Output not to exceed ±400 Vdc from
chassis potential.)
Maximum Remote Sense Line Drop
Compensation.
(Line drop must be
deducted from the supply’s maximum
output voltage.)
Input to output: 1350 Vac
1.5
V/line
Environmental Specifications
Operating Ambient Temperature
0 to 30 °C with default local sensing. Above
30 °C, derate output linearly to 0 at 70 °C.
Storage Temperature Range
–55° to 85 °C
Humidity Range
0 to 80% RH non-condensing
Operating Altitude
Up to 6,500 feet (2000 m)
Storage Altitude
Up to 50,000 feet (15 000 m)
Installation Category
Intended for use in installation category
(overvoltage category) II (IEC 1010-1 standard)
Pollution Degree
Category 2 (IEC 1010-1 standard)
6
Operating Manual for HPD Series Power Supply
Содержание sorensen hpd series
Страница 1: ...HPD Series Programmable DC Power Supply OperationManual TM 30OP 01XN Rev E www programmablepower com...
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 6: ...This page intentionally left blank ii...
Страница 8: ...This page intentionally left blank iv...
Страница 10: ...This page intentionally left blank vi...
Страница 32: ...Section 3 Load Connection and Sensing Remote Sensing 20 Operating Manual for HPD Series Power Supply...
Страница 40: ...APPENDIX RACK MOUNT INSTALLATION INSTRUCTIONS 28...
Страница 41: ...40 29 4X 9 ITEMS 10 AND 13 NOT USED FOR HPD...