PN 9000-165-VE, Rev P
USB Transfer Utility
Use this menu to upload data to a USB flash drive for use on a computer.
Uploads are carried out using a USB flash drive. It is necessary to plug
the USB flash drive into the USB port inside the AMEVision enclosure to
upload the data.
1. Press the Left or Right arrows to locate the
USB Transfer
menu and press
ENTER/MENU.
2. Press
ENTER/MENU
to access the
USB Transfer
screen.
3. From the
USB Transfer
screen, you can transfer
Sensor Parameters
and
Trend Data
, as described in the following pages.
Transfer Sensor Parameters
1. Using a standard 7/16" wrench, loosen and remove the nut on the left side
of the AMEVision enclosure to open the AMEVision enclosure door.
2. Locate the USB port inside the AMEVision enclosure (Figure 3-8) and insert
the USB flash drive into the port.
3. Select the
Transfer Sensor Parameters
button and press
ENTER/MENU
.
A screen will display asking if you have plugged in the USB drive. Select
OK
and press
ENTER/MENU
.
4. The message “
Transferring Data to USB
” is displayed.
5. The upload is successful when the next screen displays a large GREEN
check mark indicating the
Parameter Transfer
was successful.
3-14 | Thermox
®
AMEVision Display User Interface
Содержание AMEVision
Страница 1: ...AMEVision Display User Interface USER MANUAL PN 9000 165 VE Rev P 9000 185 VE Manual Views Rev A ...
Страница 12: ...PN 9000 165 VE Rev P This page intentionally left blank xii Thermox AMEVision Display User Interface ...
Страница 46: ...PN 9000 165 VE Rev P This page intentionally left blank 2 28 Thermox AMEVision Display User Interface ...
Страница 70: ...PN 9000 165 VE Rev P This page intentionally left blank 4 4 Thermox AMEVision Display User Interface ...
Страница 78: ...PN 9000 165 VE Rev P WDG V AMEVision Modbus Map A 2 Thermox AMEVision Display User Interface ...
Страница 79: ...PN 9000 165 VE Rev P EventMask 1 Bit definitions AMEVision Modbus Information A 3 ...
Страница 80: ...PN 9000 165 VE Rev P WDG 5 Command Definitions A 4 Thermox AMEVision Display User Interface ...
Страница 81: ...PN 9000 165 VE Rev P Status Mask Bit definitions AMEVision Modbus Information A 5 ...
Страница 82: ...PN 9000 165 VE Rev P Process Alarm Bit Definitions A 6 Thermox AMEVision Display User Interface ...
Страница 83: ...PN 9000 165 VE Rev P EventMask 2 Bit definitions AMEVision Modbus Information A 7 ...
Страница 84: ...PN 9000 165 VE Rev P This page intentionally left blank A 8 Thermox AMEVision Display User Interface ...