3.5.2 New parameter limits and defaults
Tmax
Range is IRT maximum to IRT m100 in 5°
increments. (default = IRT Tmax)
Tmin
Range is IRT minimum to IRT maximum –100 in 5°
increments. (default = IRT Tmin)
Interval
Range 1.5 to 90.0 in 1.5 sec increments (default = 1.5s)
Threshold
IRT Tmin to IRT Tmax in 1° increments. (default IRT Tmin)
Pre trigger
0 to 25% in increments of 1%. (default = 1)
Cursor 1
0 to 25 % in 1% increments. (default = 0)
Cursor 2
0 to 25 % in 1 % increments. (default = 0)
3.5.3 Serial parameters
If a serial or Maths card is connected to the system then the above
parameters are also available for adjustment via the serial interface.
The following table lists the mnemonics allocated to each of the parameters,
which are in line with the standard Landmark Graphic serial protocol.