![American TIM-900 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/american/tim-900/tim-900_installation-and-use-manual_2922166013.webp)
Flushing the lines means to let a given
amount of oil flow through them so as
to ensure a proper "washing" of the
whole system, a correct cleaning and
the absence of dirt, contaminated
material or processed waste inside the
lines before installing the nozzle.
The flushing operation must be carried
out on all lines, upstream the nozzle. In
case the system is equipped with more
than one nozzle, flush the lines which
supply the nozzles farthest away from
the supply pump first, then proceed
with the lines of the nozzles situated
nearer the pump.
This operation is absolutely
necessary with NEW
INSTALLATIONS or if the lines used
are contaminated.
You need not carry out this
procedure when replacing the
nozzle in use.
The flushing procedure depends on the
type and features of the system and
must be carried out by trained and
qualified personnel in compliance with
the procedures set down by the
installer.
• Make sure that the threaded end fitted
on the flexible hose is suitable for the
swivel of the TIM-900 provided with:
• Check that the TIM-900 to be installed
is complete and in good condition,
making sure that the filter is clean and
correctly installed (see paragraph “H2”).
The filter of the TIM-900, characterized
by a large filtering surface, has been
designed to guarantee a correct filtering
and a low pressure loss.
To remove and re-install the filter refer
to paragraph "H2".
The absence of the filter or its
improper installation may cause
the meter or the TIM-900 valve to
block if dirt is present in the tubes.
This situation may occur especially
during new installations.
To solve these problems consult a
qualified Service Centre.
Warning
Warning
Female thread 1/2" BSP
or
Female thread 1/2" NPT
E
ng
lis
h
Flushing the lines
E3
Preliminary checks of the TIM-900
E4
13
Содержание TIM-900
Страница 8: ...In addition the automatic dripples valve can be rotated of 240 8 ...
Страница 35: ...90 340 184 Ø BSP 1 2 Ø NPT 1 2 115 285 7 5 9 4 6 0 6 0 English Dimensions M2 35 ...
Страница 38: ......
Страница 39: ......
Страница 40: ......