![American Dynamics ADC860 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/american-dynamics/adc860/adc860_instructions-manual_2924023008.webp)
䡵
TERM. [75-ohm termination setting]
Set according to whether the signal input
into the sync signal input terminal
is
to be terminated with 75 ohms or not.
ON
: Terminated with 75 ohms
OFF : Open
Initial set ON.
Note:
The terminal is open when the power is OFF.
SYNC ADJUST menu
䡵
H PHASE [Horizontal phase adjustment]
䡵
SC COARSE [Sub-carrier phase coarse adjustment]
Adjustment of the H phase in gen-lock op-
eration. Adjust with reference to another
camera (or system).
Variable range
: 0 to 50.
Initial set
: 25.
– – S Y N C
A D J U S T – –
> T E RM .
ON
H
P H A S E
2 5
S C CO A R S E
1
S C
F I N E
1 2 8
L I N E
L 0 C K
O F F
V
CO A R S E
1
V
F I N E
1 2 8
E N D
– – S Y N C
A D J U S T – –
T E RM .
ON
> H
P H A S E
2 5
S C CO A R S E
1
S C
F I N E
1 2 8
L I N E
L 0 C K
O F F
V
CO A R S E
1
V
F I N E
1 2 8
E N D
– – S Y N C
A D J U S T – –
T E RM .
ON
H
P H A S E
2 5
> S C CO A R S E
1
S C
F I N E
1 2 8
L I N E
L 0 C K
O F F
V
CO A R S E
1
V
F I N E
1 2 8
E N D
Coarse adjustment of the SC phase in gen-
lock operation. The SC phase can be varied
by up to 90° in each direction.
Adjust with reference to another camera (or
system) and together with the SC FINE ad-
justment.
Variable range
: 1, 2, 3, 4.
Initial set
: 1.
Note :
Only the
button is effective. The
button does not operate.
Noise may be generated when END CLEAR is performed after sc coarse
adjustment. In this case, perform the sc coarse adjustment again.
7
䡵
SC FINE [Sub-carrier phase fine adjustment]
Fine adjustment of the SC phase in gen-
lock operation.
Variation range
: 0 to 255.
Initial set
: 128.
– – S Y N C
A D J U S T – –
T E RM .
ON
H
P H A S E
2 5
S C CO A R S E
1
> S C
F I N E
1 2 8
L I N E
L 0 C K
O F F
V
CO A R S E
1
V
F I N E
1 2 8
E N D
Setup functions (continued)
Note:
Adjust SC COARSE and SC FINE only after adjusting H PHASE.
Setting when the vertical sync signal of the
camera is to be locked with the AC power
frequency.
ON
: LL mode is activated.
OFF : LL mode is unactivated.
Set to OFF when using INT (internal sync)
or EXT (external sync).
Initial set
: OFF.
䡵
LINE LOCK [Line lock setting]
– – S Y N C
A D J U S T – –
T E RM .
ON
H
P H A S E
2 5
S C CO A R S E
1
S C
F I N E
1 2 8
> L I N E
L 0 C K
O F F
V
CO A R S E
1
V
F I N E
1 2 8
E N D
Notes:
• Do not apply an external sync signal in the LL mode.
• The display will be switched over between ON and OFF, how-
ever, the LL function is only available with the power frequency
of 50 [60] Hz. ( E type [U type] )
Содержание ADC860
Страница 92: ...SC96792 002...