63
Input/Output (I/O) Board Output Description (“Green” light emitting diode [L.E.D.])
1.
R_HEAT – (GREEN L.E.D.) This L.E.D. will indicate the status of the Rear Heat output. If the request
to turn on the Rear Burner is made, then the L.E.D. is ON.
2.
ALERT – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Horn output. If the request to
turn on the Horn is made, then the L.E.D. is ON.
3.
FWD – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Basket (tumbler) Forward direction
output. If the request to tumble the drum in the Forward direction is made,
then the L.E.D. is ON.
4.
REV – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Basket (tumbler) Reverse direction
output. If the request to tumble the drum in the Reverse direction is made,
then the L.E.D. is ON.
5.
AIR JET – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Air Jet output. If the request to
turn on the Air Jet is made, then the L.E.D. is ON.
6.
FAN – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Fan output. If the request to turn
on the Fan (blower) is made, then the L.E.D. is ON.
7.
F_HEAT – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Front Heat output. If the request
to turn on the Front Burner is made, then the L.E.D. is ON.
8.
PGR1 – (GREEN L.E.D.)
This is for a spare output to be programmed.
9.
PGR2 – (GREEN L.E.D.)
This is for a spare output to be programmed.
10. PGR3 – (GREEN L.E.D.)
This is for a spare output to be programmed.
11. PGR4 – (GREEN L.E.D.)
This is for a spare output to be programmed.
12. OCL1 – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Open Collector #1 output. If the
request to turn on the Open Collector #1 is made, then the L.E.D. is ON.
(Programmable and Defaulted to Front Door Open.)
13. OCL2 – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Open Collector #2 output. If the
request to turn on the Open Collector #2 is made, then the L.E.D. is ON.
(Programmable and Defaulted to Front Door Closed.)
14. OCL3 – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Open Collector #3 output. If the
request to turn on the Open Collector #3 is made, then the L.E.D. is ON.
(Programmable and Defaulted to Lint Drawer.)
15. OCL4 – (GREEN L.E.D.)
This L.E.D. will indicate the status of the Open Collector #4 output. If the
request to turn on the Open Collector #4 is made, then the L.E.D. is ON.
(Programmable and Defaulted to Front Down.)
Содержание AD-310
Страница 11: ...7 310 NON TILT GAS MODEL B DIMENSIONS AND COMPONENT LOCATION ...
Страница 12: ...8 310 NON TILT STEAM MODEL ...
Страница 14: ...10 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces ...
Страница 16: ...12 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces ...
Страница 22: ...18 ...
Страница 23: ...19 ...
Страница 24: ...20 ...
Страница 64: ...60 B I O BOARD INPUT AND OUTPUT L E D INDICATORS ...
Страница 80: ...76 ...
Страница 81: ...ADC 113110 1 01 04 00 20 2 05 07 01 20 ...