38
J. PREOPERATIONAL TESTS
ALL
dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be
preformed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Make sure the loading doors are closed and the lint drawer is closed.
3. Make sure “green” power button is in and illuminated.
4. Microprocessor controller (computer) system operational test -- to start the dryer:
a. Display will read “READY.”
b. Press “D” (preprogrammed) cycle key on the keyboard (touch pad).
5. The dryer will then start. (i.e., blower, basket [tumbler] and heat)
6. The light emitting diode (L.E.D.) display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE:
Press the “UP ARROW” to view the basket (tumbler) temperature at anytime.
NOTE:
The dryer can be stopped at anytime by pressing the “STOP/CLEAR” key. If the
temperature is above the Cool Down set point when the “STOP/CLEAR” is pressed, the
dryer will go into a Cool Down Cycle. If the “STOP/CLEAR” key is pressed again at this
point the cycle that was in progress
will
be
canceled and returned to the “READY” state. If
the temperature is below the Cool Down set point. The cycle that was in progress
will
be
canceled, and go to Wrinkle Guard.
7. When the programmed drying time has expired, the Phase 7 OPL microprocessor controller (computer) will
proceed into the Cool Down Cycle (Mode).
8. Once the Cool Down Cycle begins at the end of the heat cycle the L.E.D. display will read COOL
DOWN TEMP ___/___MINUTE REMAINING. At the end of the heat cycle the dryer will shut off the
heat, and continue the fan and basket (tumbler) until the Cool Down Time, or temperature is reached.
9. Once the Cool Down Cycle is completed the Phase 7 OPL microprocessor controller (computer) will
proceed into the Wrinkle Guard Cycle. The Audio Alert tone will sound for (the amount set in Audio
Alert ON Time). The L.E.D. display will read “WRINKLE GUARD.” The times are fixed at two (2)
minutes OFF, 2 minutes ON for a max time of 99 minutes. These times are not programmable. During the
ON time, the Blower (fan) and the (basket) tumbler will start to rotate (without heat for two [2] minutes).
The Phase 7 OPL microprocessor controller (computer) will repeat this process until the
Maximum Wrinkle Guard On Time has expired (99 minutes). The L.E.D. display will then read “CYCLE
DONE” and lockout the dryer functions until the doors are opened. It will then return to “READY.”
NOTE:
Mechanical functions of the dryer
is not
allowed during the ON time. The blower (fan)
must
be
OFF to perform mechanical functions. However the “STOP/CLEAR” key may be pressed
at any time to end a the Wrinkle Guard cycle. Mechanical functions of the dryer is allowed
during the OFF time.
Содержание AD-310
Страница 11: ...7 310 NON TILT GAS MODEL B DIMENSIONS AND COMPONENT LOCATION ...
Страница 12: ...8 310 NON TILT STEAM MODEL ...
Страница 14: ...10 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces ...
Страница 16: ...12 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces ...
Страница 22: ...18 ...
Страница 23: ...19 ...
Страница 24: ...20 ...
Страница 64: ...60 B I O BOARD INPUT AND OUTPUT L E D INDICATORS ...
Страница 80: ...76 ...
Страница 81: ...ADC 113110 1 01 04 00 20 2 05 07 01 20 ...